11. Technical Specifications
Item 3600-UK 4600-UK
PV Data (DC)
Max. input total power 6.6 kWp
Max. input power per string 3.3 kWp
Max. input voltage 550 V
Min. input voltage/Initial input voltage 125 V/150 V
MPPT voltage range 125 V~500 V
Max. input current per string 15 A
Max. input short circuit current for each MPPT 20 A
Max. inverter backfeed current to the array Negligible
Number of independent MPPT trackers 2
Number of DC inputs pairs for each MPPT 2
Connection type MC4
Battery Data (DC)
Battery capacity 3.6 kWh
Battery voltage range/nominal voltage 48.0 V~65.9 V/60 V
Battery Max. current 46.3 A
Battery nominal current 33.3 A
Discharge of depth 90% (6000 cycles)
Battery technology Li-Ion
Nominal DC/DC power 2.0 kW
DC/DC converter technology Isolated
Grid Data (AC)
Rated power (at 230V, 50 Hz) 3.6kW(*) 4.6 kW(*)
Max. apparent power 5 kVA
Nominal voltage/range 230 V/184 V~264 V
Rated power frequency/range 50 Hz/47.5 Hz~51.5 Hz
Max. current 16A 20A
Max. over-current protection 30 A
Max. allowed current for fuse protection 32 A
Inrush current
68.6 A (peak), 100 μs
Max. output fault current 420 A (peak), 4 ms
Adjustable power factor range 0.95~1~0.95
Feed-in phases/connection phases 1/1