Installation Manual
Table Of Contents
- Table of Contents
- Table of Tables
- Table of Figures
- 1. About this Manual
- 2. Safety
- 3. Package Removal and Inspection
- 4. Installation
- 5. Electrical Connections
- 5.1 The Overview of Electrical Connection
- 5.2 Opening the Front Case Cover
- 5.3 The Overview of the Connection Area
- 5.4 Battery Installation
- 5.5 Inner Wiring Connection (Power and Signal Wire Connection for BMS)
- 5.6 Closing the Front Case Cover
- 5.7 A Method of Locking the Distribution Box (Board)
- 5.8 An Installation Method of Energy Meter Electrical Connection
- 5.9 A Connecting Method of the DC Line from the PV
- 6. Communication Connection
- 7. Entering Initial Installation Information
- 7.1 Information Input Administrator
- 7.2 System Information input stage
- 7.3 PC Direct Connection and Local Setting Value
- 7.4 Web Page Connection
- 8. Operation Test
- 9. Problem Confirmation
- 10. Maintenance
- 11. Technical Specifications
- 12. Disassembly
- 13. Contact
5. Electrical Connections
The [Figure 5-23] shows the structure of the terminal block.
[Figure 5-23: Terminal Block]
After that, tie the cable to the mount using the cable tie B (larger one which is included as an
accessory) to the tie mount. You should tight the tie such that there will not be any slip when
you pull the cable with the force of 100N. And the end of outer cable surface should be
within 10 mm below the end of protrusion.
[Figure 5-24: Power Cable connection to the terminal block]
Use the screw to close the side cover and conform to the torque value of 1.2~1.8 Nm.
40 United Kingdom (Eng.) 05/2015. Rev1.1