User Manual
E-16
TROUBLESHOOTING
Power supply
220-240V 50Hz
Fan Speed Adjustment MAX MED SLEEP
CLEAN AIR
Fan Speed (m
3
/hour)
180 125 52
Rated Power (W)
27 12 4.1
Noise Level (dBA)
48 38 21
CLEAN AIR
&HUMIDIFY
Fan Speed (m
3
/hour)
180 125 52
Rated Power (W)
27 12 4.1
Noise Level (dBA)
48 38 21
Humidication (mL/hour)*1
350 280 140
Recommended Room Size (m
2
)*2
~21
High density Plasmacluster ion recommended room size (m
2
)*3
~17
Humidifying Tray Capacity (L)
1.8
Sensors Dust / Temperature & Humidity
Filter type
Dust collection HEPA *4
Deodorization Deodorizing
Cord Length (m) 2.0
Dimensions (mm) 380 (W) × 197 (D) × 570 (H)
Weight (kg) 7.2
ERROR DISPLAY 
If the error continues to occur, contact a Sharp Service Center.
DIGITAL 
INDICATION
ERROR DETAILS REMEDY
Fan motor error.
Temperature-humidity sensor error.
Unplug the unit, wait one minute, then plug he unit in 
again. 
TROUBLESHOOTING
SYMPTOM REMEDY 
(the following are not due to a malfunction)
Odor and smoke persists.
•  The air may have been dirty when the unit was plugged in.
  Unplug the unit, wait one minute, and then plug the unit in again. 
The Filter Indicator Light is on.
• Check the filters. If they appear to be extremely dirty, clean or 
  replace them. (Ref. E-11,E-12,E-13,E-14,E-15)
• Dirty or clogged dust sensor openings interfere with sensor 
  operation. Gently clean the back panel. (Ref. E-11).
• The unit may make clicking or ticking sounds when it is 
  generating ions.
•  Check to see if the filters are extremely dirty.
•  Clean or replace the filters.
•  Plasmacluster Air Purifiers emit small traces of ozone that can 
  produce an odor.
• Check to see if the unit is installed in a location that makes it 
  difficult for the sensors to detect cigarette smoke.
• Check to see if the dust sensor openings are blocked or clogged.
  If they are blocked or clogged, clean the back panel. (Ref. E-11)
• Whenever replacing the filters, connect the power cord to an 
  outlet and then press the Filter Reset Button. 
•  Check to see if the Lights OFF Mode is selected. If it is selected,
  press the Light ON/OFF Button to turn the indicator lights on. 
  (Ref. E-9)
・Check to see if the SLEEP mode is selected. (Ref. E-8)
• Clean the Humidifying Tray. Make sure that the unit is on a level 
 surface.
• Check to see if the Humidifying Tray is correctly installed. Check 
  the Humidifying Filter. 
• If the Humidifying Filter is extremely dirty, clean or replace it. 
  (Ref. E-12, E-13, E-15).
• Humidification amount gets lower when humidity reaches to the 
 proper amount (55 ~ 65%) by the actuation of humidity sensor in 
 the case of fan speed automatic.
•  There is a difference in the humidity level within the same room. 
•  The sensor have different measurement parameters.
•  If the monitor indicates TEMPERATURE, press the Display Select
 Button. (Ref. E-9)
•  The Dust Sign lights automatically change color when the dust 
  sensor detect impurities.
The Dust Sign light is green even 
when the air is not clean.
The Dust Sign light is orange or red 
even when the air is clean.
The unit makes a clicking or ticking 
sound.
Air discharged from the unit has an 
odor.
The unit does not operate when 
cigarette smoke is in the air.
The Dust Sign lights are turned off.
The Humidify Light does not light off 
when the Humidifying Tray is empty.
The water level in the Humidifying 
Tray does not decrease or decreases 
slowly.
The Dust Sign lights change color 
frequently.
There is a discrepancy between the 
unit’s Humidity Monitor and another 
hygrometer in the room.
Before calling for service, review the troubleshooting chart below to make sure 
that the problem is not a unit malfunction.
KC-F30J_EN.indd 16 2018/05/24 13:25:03