Installation guide

4-WIRE CONNECTION iNSTRUCTiONS
Before wiring the range, review the suggested power source location
drawing in Figure 2. If connecting to a 4-wire electrical system for a
new branch-circuit or mobile home use a 4-wire connection.
t Follow the power supply kit manufacturer's Installation
Instructions supplied with the strain relief clamp and install.
See Figure 8.
2 Insert the end connectors for line 1, line 2 and neutral and
tighten securely to the terminal block.
DO NOT LOOSEN the factory installed nut
connections which secure the range wiring to the terminal
block. Electrical fidlure or loss of electrical connection may
occur if these 3 nuts are loosened or removed.
3 You ml.lst disconnect the ground strap. Remove the factory
installed ground screw and plate to release the copper ground
strap from the frame of the range. Cut and discard the copper
ground strap and plate. KEEP the ground screw.
4 Connect the green ground wire lead with the eyelet to the frame
of the range with the ground screw using the same hole in the
frame where the ground screw was originally installed. See
Figure 9.
5 Make sure all screws are tightened securely and replace the
rear access cover. See Figure 7.
3-WIRE CONNECTION iNSTRUCTiONS
For existing installations ONLY, refer to Figure 10.
t Follow the power supply kit manufacturer's Installation
Instructions supplied with the strain relief clamp and install.
See Figure 8.
2 Insert the end connectors for line 1, line 2 and neutral and
tighten securely to the terminal block. See Figure 10.
DO NOT LOOSEN the factory installed nut
connections which secure the range wiring to the terminal
block. Electrical fidlure or loss of electrical connection may
occur if these 3 nuts are loosened or removed.
3 Make sure all connections are tightened securely and replace
the rear access cover. See Figure 7.
GROUNDING iNSTRUCTiONS- ONLY 3-WIRE CONNECTIONS:
A ground strap is installed on this range which connects the center
terminal of the neutral terminal block to the range chassis. The
ground strap is connected to the range by the center, lowest screw. See
Figure 10. The ground strap must not be removed unless National,
State or Local Codes do not permit use of a ground strap.
Note: If the ground strap is removed for any" reason, a separate
ground wire must be connected to the separate ground screw
attached to the range chassis and to an adequate ground source.
iNSTALLATiON MANUAL
3 & 4-WIRE PERMANENT WiRE CONNECTIONS
3-_ ire permanent connection - follo_ steps 1, 2 and 5 belong.
4-wire permanent connection - follow all steps below.
Before wiring the range, review the suggested power source location
drawings in Figure 2. If connecting to a 4-wire electrical system:
t Follow the manufacturer's Installation Instructions supplied
with the strain relief clamp and install.
2 Strip insulation away from the ends of the permanent wiring
for line 1, line 2 and neutral; also strip ground wire on 4-wire
connections. Tighten all 3 or 4-wire leads to the terminal block.
Follow wire locations shown in Figure 11.
DO NOT LOOSEN the factory installed nut
connections which secure the range wiring to the terminal
block. Electrical failure or loss of electrical connection may
occur if these 3 nuts are loosened or removed.
Note: For 3-wire permanent connection skip steps 3 and 4 and
continue with step 5.
3 Disconnect the ground strap. Remove the factory installed
ground screw and plate to release the factory installed copper
ground strap from frame of the range. Cut and discard the
copper strap from the terminal block. KEEP the ground screw,
ground plate and go to step 4.
4 Connect the green ground wire lead to the frame of the range
using the ground screw and plate as shown in Figure 12. Be sure
to install using the same hole in the frame where the ground
screw was originally installed.
5 Make sure all connections are tightened securely and replace
the rear access cover. See Figure 8.
Note: Non-terminated field wire compression connections must
be set at approximately 90 in./lbs.
Figure 9
5