[3] Copy macro block (No. 0 to 13)
If some macro blocks are already used, change numbers in order not to double the same macro block
numbers.
Especially, to change description of switch ON macro that is set to contact point search switch of multi
overlap No. 0 is difficult, change macro block number already used.
[4] How to register symbol comment characters for ladder display (message data
area)
Using symbol/comment data created on the ladder software for PC, register symbol/comment data in the
message data area of ZM series.
With these procedures, display of symbol/commend on the ladder monitor display becomes possible.
The message data area: 256 lines (pieces) x 24 groups = 6144 lines (pieces) at maximum.
Determine use ratio between normal alarm character display and symbol/comment data within this range.
Prepare symbol/comment data created.
In case of data created using JW-50SP: Extension; *.SYE or *.SYM
In case of data created using JW-100SP: Extension; *.SYC
Start up the JW-100SP software and load symbol file. (V3.02 or later version of JW-100SP)
Change file type to a specified format. [Ex.] LADDER.SYC
After loading the symbol file, save symbol/comment with ZM70 format (*.mg).