User`s manual

9-3
64 point (007300 to 007377)
007300 to 007327 : Reserved area
007330 : MW flag
007331 : MW reset
007332 to 007337 : Reserved area
007340 to 007347 : Error code storage
007354 : Non-carry flag
007355 : Error flag
007356 : Carry flag
007357 : Zero flag
007360 : 0.1 second clock
007362 : Initialize pulse
007363 : Fuse blown
007364 : 1.0 second clock
007365 : Setting value
 change switch
007366 : Normally OFF contact
007370 : Memory error
007371 : CPU error
007372 : Battery error
007373 : I/O error
007374 : Option error
007375 : Special I/O error
007376 : Expansion power
supply error
007377 : Power supply error
JW-311CU
JW-312CU
JW-321CU
JW-322CU
JW-331CU
JW-332CU
JW-341CU
JW-342CU
JW-352CU JW-362CU
2560 point (010000 to 014777 : 01000 to 01477)
448 point (015000 to 015677 : 01500 to 01567)
64 point (015700 to 015777 : 01570 to 01577)
2048 point (020000 to 023777 : 02000 to 02377)
4096 point (030000 to 037777 : 03000 to 03777)
1024 point (040000 to 041777 : 04000 to 04177)
4096 point (042000 to 051777 : 04200 to 05177)
1024 point 4096 point
512 point
53248 point 180224 point
30720 point
000000 to 015777 : 00000 to 01577
020000 to 075777 : 02000 to 07577
(100000 to 153777 : 10000 to 15377)
(154000 to 543777 : 15400 to 54377)
*
Relay
Program system
Control system
I/O control system
Program language
Type and numbers of
instruction
Instruction processing
speed
Program size
Max. No. of blocks
Max. No. of sub-programs
Memory back-up
Numbers of I/O point
Data memory
Special relay
Relay for option module
Flag for option module
Flag for I/O link
Relay for I/O link
Specifications
Items
Stored program system
Compatible cyclic calculation and interrupt dealing system
Both block refresh system and refresh system by instruction are applied.
Ladder, mnemonic
Basic instruction: 34 Application instruction: Approx. 400
Basic instruction: 33 ns and up / instruction
Application instructions: 132 ns and up / instruction
Relay for special I/O
module (basic system 1)
Relay for special I/O
module (remote I/O)
Relay for special I/O
module (basic system 2)
By built-in lithium battery. (Available for ROM operation using integrated
flash ROM.)
8K words 16K words 32K words64K words128K words256K words
16 32 64 128 256 512
256 512 1024 2048 4096 8192
Next page
* Each relay is set by module No. switch of option, special I/O, and I/O link modules.
9-3 Control module performance and communication
specifications
This section describes the performance and communication specifications of the JW-3xxCU control
modules.