User`s manual

DeviceNet (Master) Function
8-12
8
Remarks
- When setting an option module (such as the JW-22CM) is installed on the JW-34KBM basic rack
panel (and the JW-32CUM1 is installed on the same rack panel), be careful that the data memory
area does not overlap the DeviceNet area previously assigned.
[3] Setting the data memory area and system memory
The settings for the data memory area and system memory on the JW-32CUM1 (control section) are
shown below.
O: Valid setting —: Invalid setting
Data table allocation system
- In the data table allocation column, "fixed" refers to the fixed allocation scheme and "free" refers to
the free allocation scheme.
1. "Fixed allocation" means that each table area is allocated in advance.
2. "Free allocation" means that you must specify the first address of each table that is required in
system memory.
- To select "fixed" or "free," set bit 7 ON or OFF in the specified system memory location (4th byte) of
each table. - See pages 8-13 and 8-14.
Basic operation
mode
Data table allocation system
Fixed Free
(See page)
Master Slave Setting item
-As follows
O—
Input/output table (Top address
when "free" allocation is selected)
#300 to #303
-8-13, 8-21
OO
Diagnostic table (Top address when
"free" allocation is selected)
39000 to
39377
#304 to #307
-8-13, 8-40
O—
"Explicit" message table: Request
(Top address when "free" allocation
is selected)
39400 to
39565
#310 to #313
-8-3, 8-30
O—
"Explicit" message table: Response
(Top address when "free" allocation
is selected)
39600 to
39765
O—
Scan list table (Top address when
"free" allocation is selected)
E0000 to
E0777
#314 to #317
-8-14, 8-29
O—
Data length when editing the scan
list
#321
-8-14
O—ISD (communication monitor time)
#324
#325
-8-15
O—EPR (communication monitor time)
#326
#327
O—
Output status to slave stations when
the control section is stopped.
#330
—O
Top address of the input/output table
(slave)
#360 to #363
-8-16
—ONumber of input/output bytes (slave) #364 to #367
—O
Latch/clear the slave area when a
communication error occurs. (slave)
#370
—O
Response time to the master station
(slave)
#371
#372
2000 to
2777
2000