[5] Allocation example of relay number
(1) Example of auto registration
This is to show the relay numbers in the following system configuration.
00140
00157
00160
00177
00200
00217
00220
00237
00240
00277
00300
00317
00320
00337
00340
00357
00040
00057
00060
00077
00100
00117
00120
00137
Rack No.1
16 points input module
16 points output module
8 points input module
8 points output module
Special module
Vacant slot
Special (64 points output) module
32 points input module
Rack No.0
Special, I/O link, Option module
Special (64 points output) module
Power
supply
module
Control
module
(JW-32CUM1)
16 points input module
8 points output module
(2) Example of table creation
This is to show the relay numbers when the top address of rack number 1 is set at コ0200 in the
following system configuration.
02000
02017
02020
02037
02040
02057
02060
02077
02100
02137
02140
02157
02160
02177
02200
02217
00040
00057
00060
00077
00100
00117
00120
00137
Rack No.1
16 points input module
16 points output module
8 points input module
8 points output module
Special module
Vacant slot
Special (64 points output) module
32 points input module
Rack No.0
16 points input module
8 points output module
Special, I/O link, Option module
Special (64 points output) module
Power
supply
module
Control
module
(JW-32CUM1)