Instruction manual

6 - 13
4) Parallel input instruction: codeF004H
• Output the preset data (ON/OFF) to the parallel I/O terminal block (16 terminals).
[Command]
:
Station No.
F004D0D1
••• •••
D15 SC CR
(H) (L )
• Output data D0 to D15: 0 = OFF, 1 = ON
:
Station No.
F004RCRC RC RC SC SC CR
(H)
••• •••
(L) (H) (L )
[Response]
5) Setting gain/offset: code F005H
• Change the gain (contrast) and the offset (brightness) of the specified camera
[Command]
:
Station No.
F005
Preset value
SC SC CR
10
2
10
1
10
0
(H) (L )
Camera No.: 0 =Camera 1, 1 = Camera 2
gain/offset setting: 0 = gain, 1 = offset
• Preset value: 0 to 255
[Response]
:
Station No.
F 005RCRCRC RC SC SC CR
(H)
••• •••
(L) (H) (L )