Instruction manual

6 - 11
9) Light level automatic adjustment
• When the illuminance monitor is executed and it turns out as "NG", automatically adjusts the
light level using one of the following methods, and reads the result of the last illuminance
monitor.
Lighting automatic dimmer function Shutter speed automatic adjustment
[Command]
Camera
:
Station No.
0118
SC SC CR
No. (H) (L)
[Response]
Illuminance
:
Station No.
0118RCRCRCRC
Object type
Result
(H) ••• ••• (L )
10
2
10
1
10
0
10
-1
2 pt
Illuminance
Result
SC SC CR
10
2
10
1
10
0
10
-1
(H) (L)
10) Self-diagnosing: code 0300H
• Checks for abnormalities of hardware at the image processing of IV-S51M.
• Diagnosis
RAM related (read after light), FROM related (system program checksum)
[Command]
:0300SCSCCR
(H) (L )
Station No.
[Response]
:
Station No.
0300RCRCRCRC SC SC CR
(H)
••• ••• (L ) (H ) (L )
• RC = 0 at the normal state, RC 0 at the abnormal state
• Abnormality code is described in the separate sheet.