Instruction manual
6 - 9
5) Result data reading 1: code 0111H
• Reads the numeric value result of the last measurement.
• The result data of the measurement program will be divided into packets by each 512 bytes
(128 data
×
4 bytes) from the beginning, and sent as the response.
[Command]
Execution
:
Station No.
010RCRCRCRC
Object type
Camera
SC SC CR
(H)
••• •••
((L) H) (L) No. (H) (L)
:1 Numeric value result
data
:
Station No.
0110SCSCCR
(H) (L )
• The first measurement execution command is specified as "0" for the specified packet No.
[Response]
• Current packet No., Final packet No.
:
Station No.
0111 SCSCCR
(H) (L )
6) Result data reading 1: code 0112H
• Reads the arithmetic result of the last measurement.
• The result data of the measurement program will be divided into packets by each 512 bytes
(64 data × 8 bytes, double precision floating decimal point) from the beginning, and sent as the
response.
[Command]
Execution
:
Station No.
0112
Object type
camera
SC SC CR
(H) (L ) No. (H) (L )
:
Station No.
0111 RCRCRCRC
(H)
•••
•••
(L) (H) (L)
Execution
Object type
camera
No.
• The first measurement execution command is specified as "0" for the specified packet No.
[Response]
• Current packet No., Final packet No.
S
CSCCR
(H) (L )
Numeric value result
data