Instruction manual
6 - 8
3) Measurement execution 3: code 0012H
 • Execute all of the measurement programs for a specified object type or corresponding
 measurement program for the specified camera.
 • The arithmetic result of the measurement program will be divided into packets by each 512
 bytes 
(64 data × 8 bytes, double precision floating decimal point) from the beginning, and sent
 as the response.
 [Command]
:
Station No.
0012
Object type
Camera
SC SC CR
(H) (L ) No. (H) (L )
 •   The first measurement execution command is specified as "0" for the specified packet No.
 [Response]
Execution
:
Station No.
  0012RCRCRCRC
Object type
Camera
(H) •••   ••• (L) (H) (L ) No.
CSCCR
(H) (L )
Numeric value result
data
 •   Current packet No.,   Final packet No.
4) Result data reading 1: code 0110H
 • Reads the numeric value result of the last measurement.
  • The result data of the measurement program will be divided into packets by each 512 bytes
 (128 data 
×
 4 bytes) from the beginning, and sent as the response.
 [Command]
:
Station No.
0110SCSCCR
(H) (L )
 [Response]
Execution
:
Station No.
010RCRCRCRC
Object type
Camera
SC SC CR
(H)
••• •••
((L) H) (L) No. (H) (L)
:1 Numeric value result
data