Instruction manual

6 - 8
3) Measurement execution 3: code 0012H
• Execute all of the measurement programs for a specified object type or corresponding
measurement program for the specified camera.
• The arithmetic result of the measurement program will be divided into packets by each 512
bytes
(64 data × 8 bytes, double precision floating decimal point) from the beginning, and sent
as the response.
[Command]
:
Station No.
0012
Object type
Camera
SC SC CR
(H) (L ) No. (H) (L )
The first measurement execution command is specified as "0" for the specified packet No.
[Response]
Execution
:
Station No.
0012RCRCRCRC
Object type
Camera
(H) ••• ••• (L) (H) (L ) No.
CSCCR
(H) (L )
Numeric value result
data
Current packet No., Final packet No.
4) Result data reading 1: code 0110H
• Reads the numeric value result of the last measurement.
• The result data of the measurement program will be divided into packets by each 512 bytes
(128 data
×
4 bytes) from the beginning, and sent as the response.
[Command]
:
Station No.
0110SCSCCR
(H) (L )
[Response]
Execution
:
Station No.
010RCRCRCRC
Object type
Camera
SC SC CR
(H)
••• •••
((L) H) (L) No. (H) (L)
:1 Numeric value result
data