Instruction manual

6 - 7
Ex. 3 Measurement 1 Point sensor
• 8 points are handled by 1 byte.
• Black & white = FA(H)
FA
11111010
Point No. P7 P6 P5 P4 P3 P2 P1 P0
Black & white White White White White White Black White Black
0 = Black, 1 = White
[Example of HMI]
2) Measurement execution 2: code 0011H
• Execute all of the measurement programs for a specified object type or corresponding
measurement program for the specified camera.
• The result data of the measurement program will be divided into packets by each 512 bytes
(128 data × 4 bytes) from the beginning, and sent as the response.
[Command]
Execution
:
Station No.
0011
Object type
camera
SC SC CR
(H) (L ) No. (H) (L )
[Output data (general purpose serial)] F C1 BRT
Packet 0 Measurement 1 Registration 0 ~7 1 bytes
Registration 8 ~ 15 1 bytes
The first measurement execution command is specified as "0" for the specified packet No.
[Response]
:
Station No.
0011 RCRCRCRC
(H) ••• ••• (L) (H) (L )
Execution
Object type
camera
No.
Current packet No., Final packet No.
Numeric value result SC SC CR
data (H ) (L)