Setting Measurement Conditions
3-40
3
[5] Halt on NG measurement
You can stop all measurements when an NG image
(according to the final evaluation results) occurrs while
operating the IV-S30.
Select " HALT ON NG MEAS" on the "OBJECT
TYPE SYS." menu.
Shown below is an example of an NG image that occurred during measurement 1.
NG occurred
(Setting whether to stop measurements when an NG occurs)
"No" "Yes"
Wait for trigger input
Processing measurement 0, camera 1
Processing measurement 0, camera 2
Processing measurement 1
Processing measurement 2
Processing measurement 3
Processing measurement 4
- Stops processes
of measurements 2
to 4
Displayed when the
IV-S32MX/S33MX
is used.
NO
YES
NO(NG MEAS DISP)
1
REGST NG IMG YES
2
HALT ON NG MEAS YES
3
MNTR LIGHT LVL(CAM1) YES
4
LIGHT LV COND (TO NEXT SUB-BENU)
5
MNTR LIGHT LVL(CAM2) YES
6
LIGHT LV COND (TO NEXT SUB-MENU)
7
MOVE ALL WINDOW (TO NEXT SUB-MENU)
OBJ-TYPE SYS. SCREEN SAVE
F C1 BRT
22
2
22HALT ON NG MEAS
Desciption
NO
Even if an NG image (final evaluation result) is detectd while
operating the IV-S30, the system will continue making
measurements.
YES
When an NG image is detected (according to the final
evaluation result) while operating the IV-S30, the controller
will stop making measurements.
NO(NG MEAS DISP)
Even if an NG image (final evaluation result) is detected while
operating the IV-S30, the system will continue making
measurements. But, it displays the ocurred NG
measurements at first.