User`s manual
Table Of Contents
- Safety Precautions
- Table of contents
- Chapter 1: Outline
- 1-1 Features
- 1-2 Controller
- 1-3 Measurement program
- [1] Positional deviation measurement
- [2] Degree of match inspection
- [3] Lead inspection
- [4] BGA/CSP inspection (IV-S32M/S33M)
- [5] Area measurement by binary conversion
- [6] Object counting by binary conversion
- [7] Object identification by binary conversion
- [8] Point measurements
- [9] Distance and angle measurement
- [10] Multiple position measurement (IV-S33M)
- [11] Multiple degree of match inspection (IV-S33M)
- Chapter 2 : Precautions for Use
- Chapter 3 : System Configuration
- Chapter 4 : Part Names and Functions
- Chapter 5 : Connection and Installation Methods
- Chapter 6 : Setting and Operating Outlines
- Chapter 7 : Simplified Menu Operation
- 7-1 Operation screen
- 7-2 Image display
- 7-3 Setting functions that are different with each controller
- 7-4 Setting procedures
- 7-5 Setting the operation conditions
- 7-6 Setting object types
- 7-7 Setting the shutter speed
- 7-8 Setting the positioning conditions
- 7-9 Setting the existence inspection conditions
- 7-10 Measurement triggering
- 7-11 Saving data
- 7-12 Specify the system conditions
- Chapter 8 : Specifications
- Chapter 9 : Operation Examples
- Glossary
- Appendix
- Alphabetical Index

7-11
Simplified Menu Operation
7
7-6 Setting object types
Specify the type of object to be measured. A number of object types can be registered (16 types (0 to 15)
on the IV-S31M, 32 types (0 to 31) on the IV-S32M and 64 types (0 to 63) on the IV-S33M).
ËË
ËË
Ë Setting procedure
1. Move the cursor to the "CHG-TYPE" item on the MAIN OPS MENU using the left and right keys and
then press the SET key.
- The object type setting list will be displayed.
2. Move the cursor to the object number that you want to set up using the up and down keys, and press
the SET key.
- The object type conditions can then be specified. ( : Registered, : Not registered)
- The object type currently selected by the cursor will be the place where the measurement and
evaluation conditions are stored and the operation will be executed.
- After setting up the object type, if you press the SET key again, the settings will be ignored.
E.g.) The registered conditions for object type 00
F.IMG C1 L
VX.XX
(TYPE00)
MEAS XXXXms 2000-08-01 10:30
MEASURE0 CAM1 POSITIONING
00
01
02
08
09
10
16
17
18
24
25
26
○
×
×
×
×
×
×
×
×
×
×
×
32
33
34
40
41
42
48
49
50
56
57
58
×
×
×
×
×
×
×
×
×
×
×
×
When the IV-S33M is used
When the IV-S31M is used 00 to 15
When the IV-S32M is used 00 to 31
F.IMG C1 L
VX.XX
(TYPE00)
MEAS XXXXms 2000-08-01 10:30
MEASURE0 CAM1 POSITIONING
CHG-TYPE
POSI-COND
POSI-EVAL.
OPS-CND
SYS-CND
ADJ-CONTRAST
SAVE
SHUTTER
X0~7 Y0~7 READY
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
Object type No. (00 to 63)
O: Registered ×: Not registered
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
When the IV-S33M is used, "Object type number 00 Yes/No" will be
displayed. Select "Yes" by pressing the left and right cursor keys.