Follow the procedure described below when turning ON the power to the IV-S31M/S32M/S33M
controller, and the [POWER ON SETTING] menu will be displayed on the monitor.
1. Turn ON the power to the controller, while holding down the ESC key.
2. Keep pressing the ESC key down for approx. 9 sec., after turning ON the power and the menu will be
displayed.
[1] Operations menu lock
To prevent accidental changes to conditions you have set, the MAIN OPS MENU can be locked so that
the screen cannot be changed to SET-SCRN. The operation can only be carried out on the [POWER ON
SETTIN] menu.
Operation procedure
1. On the [POWER ON SETTING] menu, move the cursor to item 1MAIN OPS MENU with the up
and down keys, and press the SET key.
2. Move the cursor to UNLOCK or LOCK with the left and right keys, and press the SET key.
3. Move the cursor to item 3OPERATION with the up and down keys, and press the SET key. Press
the SET key once more.
- The IV-S30 saves the settings in the flash memory and the screen will return to the SELECT
MENU.
Display when the MAIN OPS MENU is locked
[2] Change the Japanese or English display mode
The language used on the screen scan be set to Japanese or English. Select the [POWER ON SETTING]
menu.
Operation procedure
1. Move the cursor to item 2DISPLAY MODE with the up and down keys, and press the SET key.
2. Move the cursor to JAPANESE or ENGLISH with the left and right keys.
3. Move the cursor to item 3OPERATION with the up and down keys, and press the SET key. Press
the SET key once more.
- The screan will return to the MAIN OPS MENU.
POWER ON SETTING
1 MAIN OPS MENU UNLOCKLOCK
2 DISPLAY MODE JAPANESEENGLISH
3 OPERATION
1 MAIN OPS MENU
Description
UNLOCK
LOCK
All of the operating conditions for the
IV-S30 can be changed.
The MAIN OPS MENU is locked and
no change can be made.
"LOCK" will be
displayed on the
MAIN OPS MENU
T.IMG C1 L
LOCK FULL VX.X
(TYPE00)
OK
MEAS XXXXXXms
MEASURE 0 CAM1 POSI-DEVIATION
This is only
displayed when
using the IV-S33M