User`s manual
Table Of Contents
- Safety Precautions
- Table of contents
- Chapter 1: Outline
- 1-1 Features
- 1-2 Controller
- 1-3 Measurement program
- [1] Positional deviation measurement
- [2] Degree of match inspection
- [3] Lead inspection
- [4] BGA/CSP inspection (IV-S32M/S33M)
- [5] Area measurement by binary conversion
- [6] Object counting by binary conversion
- [7] Object identification by binary conversion
- [8] Point measurements
- [9] Distance and angle measurement
- [10] Multiple position measurement (IV-S33M)
- [11] Multiple degree of match inspection (IV-S33M)
- Chapter 2 : Precautions for Use
- Chapter 3 : System Configuration
- Chapter 4 : Part Names and Functions
- Chapter 5 : Connection and Installation Methods
- Chapter 6 : Setting and Operating Outlines
- Chapter 7 : Simplified Menu Operation
- 7-1 Operation screen
- 7-2 Image display
- 7-3 Setting functions that are different with each controller
- 7-4 Setting procedures
- 7-5 Setting the operation conditions
- 7-6 Setting object types
- 7-7 Setting the shutter speed
- 7-8 Setting the positioning conditions
- 7-9 Setting the existence inspection conditions
- 7-10 Measurement triggering
- 7-11 Saving data
- 7-12 Specify the system conditions
- Chapter 8 : Specifications
- Chapter 9 : Operation Examples
- Glossary
- Appendix
- Alphabetical Index

5-19
Connection and Installation Methods
5
(3) I/O port
The input/output terminals are isolated by photocouplers, to prevent malfunctions due to noise. Use
them within the rated range. The specifications of the input/output ports are listed below.
12/24 VDC
10.5 to 26.4 VDC
ON: 10.5 V or less OFF: 3 V or more
ON: 3 mA or less OFF: 0.9 mA or more
3.3 k ohm
12/24 VDC
10.5 to 27 VDC
100 mA DC
Photo MOS open drain
30 ohms or less
Photo MOS isolation
3 ms or less (OFF to ON, ON to OFF)
Rated input voltage
Input voltage range
Input voltage level
Input current level
Input impedance
Rated output voltage
Load voltage range
Rated max. output current
Output type
ON resistance
Isolation method
Input
Item Rating
Output
Response time
(4) Wiring to the controller (IV-S31M/S32M/S33M)
X0 X7 Y0 Y7 READYCOM COM
L LL
Power
supply
Load
Input Output
Fuse
(
0.5A)
Power
supply
Controller
-
+
+
-
Protective element
(Power supply
limit: 33 V)
Result of logical calculation output
- Specify in the FINAL-OUTPUT on the [TYPE MEAS COND] menu.
Y0
to Y7
READY
These signals will turn ON when the measurement start input is enabled.
- For information about the timing chart and other details, see "Setting the In-
put/Output Conditions" in the IV-S30 User’s Manual (Function and Operation).
(2) Output terminals (OUTPUT) Y0 to Y7 and READY