User`s manual
Table Of Contents
- Safety Precautions
- Table of contents
- Chapter 1: Outline
- 1-1 Features
- 1-2 Controller
- 1-3 Measurement program
- [1] Positional deviation measurement
- [2] Degree of match inspection
- [3] Lead inspection
- [4] BGA/CSP inspection (IV-S32M/S33M)
- [5] Area measurement by binary conversion
- [6] Object counting by binary conversion
- [7] Object identification by binary conversion
- [8] Point measurements
- [9] Distance and angle measurement
- [10] Multiple position measurement (IV-S33M)
- [11] Multiple degree of match inspection (IV-S33M)
- Chapter 2 : Precautions for Use
- Chapter 3 : System Configuration
- Chapter 4 : Part Names and Functions
- Chapter 5 : Connection and Installation Methods
- Chapter 6 : Setting and Operating Outlines
- Chapter 7 : Simplified Menu Operation
- 7-1 Operation screen
- 7-2 Image display
- 7-3 Setting functions that are different with each controller
- 7-4 Setting procedures
- 7-5 Setting the operation conditions
- 7-6 Setting object types
- 7-7 Setting the shutter speed
- 7-8 Setting the positioning conditions
- 7-9 Setting the existence inspection conditions
- 7-10 Measurement triggering
- 7-11 Saving data
- 7-12 Specify the system conditions
- Chapter 8 : Specifications
- Chapter 9 : Operation Examples
- Glossary
- Appendix
- Alphabetical Index

5-15
Connection and Installation Methods
5
[3] Connecting a power supply
Connect a commercially available constant-voltage power supply to the power terminals (POWER: +24
V, 0 V) on the controller (IV-S31M/S32M/S33M). Use a 24 VDC ± 10%, 500 mA or more constant-
voltage power supply.
- Use an individual power supply to supply power to the controller. If the power supply is used to power
other equipment, measurement errors may occur.
- Check the polarity of the power supply terminals, +24 V and 0 V. If power is supplied with the polarity
inverted, the controller may be damaged.
- Only connect or disconnect the camera cable and other equipment while the power is OFF.
Controller (IV-S31M/S32M/S33M)
OUTPUT
INPUT
Y7Y0 Y1 Y2 Y3 Y4 Y5 Y6
COM
COM
+24V
X7X0 X1 X2 X3 X4 X5 X6
READY
0V
IV-S3*M
OUTPUT
INPUT
POWER
Y7Y0 Y1 Y2 Y3 Y4 Y5 Y6
COM
COM
+24V
X7X0 X1 X2 X3 X4 X5 X6
READY
0V
VIDEO
CAMERA1
CAMERA2
USB
RS232C/RS422
REMOTE
Power supply terminal
(POWER : 0V)
24 VDC
(+) (-)
Fuse
(1A)
Constant-voltage
power supply
Power supply terminal
(POWER: + 24V)
Frame ground
terminal
Frame ground
terminal
This distance must be
as short as possible.
(Recommended distance:
less than 1 m)
To improve the noise resistance of the constant-voltage power supply connected to the
controller (IV-S31M/S32M/S33M), observe the following precautions.
- Ground the FG terminal of the constant-voltage power supply according to the class 3
grounding.
- The power line between the controller and the constant-voltage power supply must be
as short as possible. (Recommended distance: less than 1 m)
Do not run the power supply line near any noise generating sources, such as electric
motor lines.
- Use twisted-pair wire for the power supply line.
Note