User`s manual
Table Of Contents
- Safety Precautions
- Table of contents
- Chapter 1: Outline
- 1-1 Features
- 1-2 Controller
- 1-3 Measurement program
- [1] Positional deviation measurement
- [2] Degree of match inspection
- [3] Lead inspection
- [4] BGA/CSP inspection (IV-S32M/S33M)
- [5] Area measurement by binary conversion
- [6] Object counting by binary conversion
- [7] Object identification by binary conversion
- [8] Point measurements
- [9] Distance and angle measurement
- [10] Multiple position measurement (IV-S33M)
- [11] Multiple degree of match inspection (IV-S33M)
- Chapter 2 : Precautions for Use
- Chapter 3 : System Configuration
- Chapter 4 : Part Names and Functions
- Chapter 5 : Connection and Installation Methods
- Chapter 6 : Setting and Operating Outlines
- Chapter 7 : Simplified Menu Operation
- 7-1 Operation screen
- 7-2 Image display
- 7-3 Setting functions that are different with each controller
- 7-4 Setting procedures
- 7-5 Setting the operation conditions
- 7-6 Setting object types
- 7-7 Setting the shutter speed
- 7-8 Setting the positioning conditions
- 7-9 Setting the existence inspection conditions
- 7-10 Measurement triggering
- 7-11 Saving data
- 7-12 Specify the system conditions
- Chapter 8 : Specifications
- Chapter 9 : Operation Examples
- Glossary
- Appendix
- Alphabetical Index

5-2
5
Connection and Installation Methods
When using the IV-60LD
This paragraph describes how to use Sharp IV-60LD LED lighting equipment. For details about the
installation and wiring of the IV-60LD, see the instruction manual.
The distance between the IV-60LD and an object (distance at which to install lighting equipment) should
be approximately 150 mm, and the lit area is approximately 50 mm ¥ 50 mm.
If the lighting distance is reduced approximately 60 mm, the lighting may be uneven.
87mm
A
50mm
50mm
77.3mm
Camera center
IV-S30 camera
Camera center
Light area
- View A
Workpiece surface
(Object to be
measured)
Lighting distance : 150mm
Camera angle bracket
IV-60LD body
(Lighting section)
IV-60LD body IV-60LD body
IV-S30 camera
IV-S30 camera
IV-60LD body
When the light is projected from above the object and if reflection off the object influences the image
processing, try the following countermeasures.
1Tilt the camera center axis (within a range that does not affect the image processing) to move away
from the light reflected from the object.
2Separate the camera from the lighting equipment. Install the IV-60LD lighting equipment so that it will
shines from an angle that prevents creation of the reflection.
- One light - Two lights
Reflected light
Workpiece surface
(Object to be
measured)
IV-S30 camera
IV-60LD body