User`s manual

Table Of Contents
3-6
System Configuration
3
(3) When a personal computer is connected
- Purpose/application
Measurement is started by a CCD trigger (sampling start input: personal computer), and the
measurement data is output to a personal computer. The object type number is selected by the
personal computer.
IV-S3M
OUTPUT
INPUT
POWER
Y7Y0 Y1 Y2 Y3 Y4 Y5 Y6
COM
COM
24V
X7X0 X1 X2 X3 X4 X5 X6
READY
0V
VIDEO
CAMERA1
CAMERA2
USB
RS232C/RS422
REMOTE
Camera 1 (image + CCD trigger)
Camera 2 (image)
Controller
Power supply
(24 VDC)
Monitor
Start sampling input
Object type selection, data
Personal
computer
(2) When a programmable controller is connected
- Purpose/application
Measurement is started by a CCD trigger (sampling start input: a photo sensor etc.), and the
measurement data is output to a programmable controller. The object type number is selected by the
programmable controller.
IV-S3M
OUTPUT
INPUT
POWER
Y7Y0 Y1 Y2 Y3 Y4 Y5 Y6
COM
COM
24V
X7X0 X1 X2 X3 X4 X5 X6
READY
0V
VIDEO
CAMERA1
CAMERA2
USB
RS232C/RS422
REMOTE
Start sampling input
(a photo sensor or proximity
sensor etc.)
Data (computer link)
Object type selsection
(parallel I/F)
Programmable
controller
Remote key pad
Camera 1 (image + CCD trigger)
Camera 2 (image)
Controller
Power supply
(24 VDC)
Monitor