- Chapter 1: Outline
- 1-1 Features
- 1-2 Controller
- 1-3 Measurement program
- [1] Positional deviation measurement
- [2] Degree of match inspection
- [3] Lead inspection
- [4] BGA/CSP inspection (IV-S32M/S33M)
- [5] Area measurement by binary conversion
- [6] Object counting by binary conversion
- [7] Object identification by binary conversion
- [8] Point measurements
- [9] Distance and angle measurement
- [10] Multiple position measurement (IV-S33M)
- [11] Multiple degree of match inspection (IV-S33M)
- Chapter 2 : Precautions for Use
- Chapter 3 : System Configuration
- Chapter 4 : Part Names and Functions
- Chapter 5 : Connection and Installation Methods
- Chapter 6 : Setting and Operating Outlines
- Chapter 7 : Simplified Menu Operation
- 7-1 Operation screen
- 7-2 Image display
- 7-3 Setting functions that are different with each controller
- 7-4 Setting procedures
- 7-5 Setting the operation conditions
- 7-6 Setting object types
- 7-7 Setting the shutter speed
- 7-8 Setting the positioning conditions
- 7-9 Setting the existence inspection conditions
- 7-10 Measurement triggering
- 7-11 Saving data
- 7-12 Specify the system conditions
- Chapter 8 : Specifications
- Chapter 9 : Operation Examples
- Glossary
- Appendix
- Alphabetical Index

9-16
Operation Examples (Standard menu: Positional deviation measurement)
9
1
REGISTER NO.
0(0~7)
3
1
T.IMG C1 L
2
4
1
3
Search area
Reference area
(5) Setting the measurement number ("MEASUREMENT 1" is selected with the IV-S33M)
(6) Setting the registration number and the mode (REGISTER NO. 0 and 1P-SCH are selected
in this example)
To the next page
Continued from the previous page
1. Move the cursor to "MEAS-COND"
using the left and right keys, and press
the SET key.
2. Move the cursor to the "2REGISTER
NO." item on the lower window using
the up and down keys. Then press the
SET key.
3. Move the cursor to "1P-SCH" using the
left and right keys, and press the SET
key.
4. Move the cursor to the "4MDL 0" item
using the up and down keys, and press
the SET key.
5. Move the cursor to the "S" below the
registration number 00, and press the
SET key.
1. Move the cursor to the
"5MEASUREMENT 1" item using the
up and down keys, and press the SET
key.
2. Move the cursor to "NO" using the left
and right keys, and press the SET key.
3. Move the cursor to the "1MEAS SE-
LECTION" item on the lower window
using the up and down keys. Then
press the SET key.
(7) Image adjustment
1. Press the SEL key.
- The image taken by camera 1 will be displayed.
- When the image is so bright that the menu display is difficult to see, press the TRG/BRT key to reduce
the brightness of the image. The indicator in the upper right corner of the screen will change from "H"
to "L."
2. To display the image of the object measured clearly, adjust the focus and iris opening of the camera lens
(page 4-1).
3. Press the SEL key to change the screen to the freeze mode.
- The indicator in the upper right corner of the screen will change from T.IMG to F.IMG.
- To set a threshold for a binary area, make sure the machine is displaying the freeze screen.
(For details about the through and freeze modes, see page 7-4.)
4. Press the ESC key to display all of the gray scale search conditions.
Press the TRG/BRT key and the
brightness of the screen will change
between L and H.
Indicates that Camera 1 is selected.
[TYPE MEAS COND]
[MEAS COND]
⑥
MEASUREMENT 1
MEAS-BIN-AREA C1
(MEAS-COND)
①
DTECT PRECISION
STANDARD HIGH
②REGISTER NO. 0(0~7) NO 1P-SCH 2P-SCH
1P-EDGE 2P-EDGE 1P-SCH
+
1P-EDGE
③DTECT ANGL NO YES(
±
15°
±
30°
±
45゜360°)
REGISTER NO.
④MDL 0
⑤MDL 1
NUMERIC CALC
OPS-MENU RETURN LOCK EVALUATION DST&ANGL NUM-CALC OUT-COND
00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15
S ×××××××
××××××××
××××××××××××××××
3
1
4
5
[TYPE MEAS COND]
[MEASUREMENT 1]
①
OBJECT TYPE NO.
00(0~63) NO YES
②SELECT CAMERA CAM1&2 CAM1&NG-IMG
③
IMG PRE-PROCESS
(TO NEXT SUB-MENU)
④
MEASURE 0 CAM1
NO (MEAS-COND) NO
⑤
MEASURE 0 CAM2
NO (MEAS-COND) NO
⑥
MEASUREMENT 1
NO
(MEAS-COND)
⑦
MEASUREMENT 2
NO
(MEAS-COND)
⑧
MEASUREMENT 3
NO
(MEAS-COND)
⑨
MEASUREMENT 4
NO
(MEAS-COND)
①
MEAS SELECTION
NO POSI-DEVIATION CHK-DEG-MATCH
INSPECT-LEAD INS PECT-BGA/CSP
MEAS-BIN-AREA CNT-BIN-OBJ LABEL-BIN-OBJ
POINT-MEAS MULTI-POSI MULTI-MATCHES
②SELECT CAMERA CAM1 CAM2
③
CHNG GRAY LEBEL NO YES(00.0TIMES
γ+ γ -
CHNG-L
INCRS-M
)
④
SPACE FILTER
NO NUM-OF-TIMES 0(0~5)
OPS-MENU SAVE LOCK TITLE FINAL-CALC FINAL-OUTPUT I/O SYSTEM
OPS-MENU RETURN LOCK
2