User`s manual
Table Of Contents
- Safety Precautions
- Table of contents
- Chapter 1: Outline
- 1-1 Features
- 1-2 Controller
- 1-3 Measurement program
- [1] Positional deviation measurement
- [2] Degree of match inspection
- [3] Lead inspection
- [4] BGA/CSP inspection (IV-S32M/S33M)
- [5] Area measurement by binary conversion
- [6] Object counting by binary conversion
- [7] Object identification by binary conversion
- [8] Point measurements
- [9] Distance and angle measurement
- [10] Multiple position measurement (IV-S33M)
- [11] Multiple degree of match inspection (IV-S33M)
- Chapter 2 : Precautions for Use
- Chapter 3 : System Configuration
- Chapter 4 : Part Names and Functions
- Chapter 5 : Connection and Installation Methods
- Chapter 6 : Setting and Operating Outlines
- Chapter 7 : Simplified Menu Operation
- 7-1 Operation screen
- 7-2 Image display
- 7-3 Setting functions that are different with each controller
- 7-4 Setting procedures
- 7-5 Setting the operation conditions
- 7-6 Setting object types
- 7-7 Setting the shutter speed
- 7-8 Setting the positioning conditions
- 7-9 Setting the existence inspection conditions
- 7-10 Measurement triggering
- 7-11 Saving data
- 7-12 Specify the system conditions
- Chapter 8 : Specifications
- Chapter 9 : Operation Examples
- Glossary
- Appendix
- Alphabetical Index

9-13
9
Operation Examples (Standard menu: Area measurement by binary conversion)
1
4
1
4
2
3
6
THRESHOLD U.LM255 L.LM100(0~255)
OPS-MENU RETURN LOCK EVALUATION
L.LM100(0~255)
2
REGISTER 00
000000~002000
[OUTPUT]
Y0
To the next page
Continued from the previous page
(10) Setting the binary area conditions (threshold)
1. Move the cursor to the "6THRESHOLD" item using the up and down keys, and press the SET key.
2. Move the cursor to the "L.LM" item and then press the SET key.
3. Move the cursor to each digit using the left and right keys, and increase or decrease the values using the
up and down keys.
This cursor will move to the left and right.
- To set the threshold parameters, see the section in the Glossary which describes them.
- After determining the lower limit, press the SET key, and then the ESC key.
4. Move the cursor to the bottom line using the up and down keys, and select the "EVALUATION" item
using the left and right keys. Then press the SET key.
- The [EVALUATION COND] menu will be displayed.
(11) Setting the evaluation conditions and result output
1. Move the cursor to "2REGISTER 00" and press the SET key.
2. Move the cursor to the upper limit position with the left and right keys, and press the SET key.
- Select the digit to change with the left and right keys, and then set the value to 002000 with the up and
down keys.
- After specifying the upper limit value, press the SET key, and then the ESC key.
3. Move the cursor to "OUTPUT" using the left and right keys.
- Select "Y0" using the up and down keys, and press the SET keys.
4. Move the cursor to the "OPS-MENU" item using the up and down keys.
- The screen will return to the MAIN OPS MENU.
[EVALUATION COND]
①CHNG REG
[TEST RESULT] [OUTPUT]
②CONDITION SET RESET AUTO(±10%)
③
REGISTER 00
000000~245760
A00= NO
④
REGISTER 01
000000~245760
⑤
REGISTER 02
000000~245760
⑥
REGISTER 03
000000~245760
⑦
REGISTER 04
000000~245760
⑧
REGISTER 05
000000~245760
⑨
REGISTER 06
000000~245760
⑩
REGISTER 07
000000~245760
⑪
TEST EXEC (WITH-POSI.ADJ WITHOUT-POSI.ADJ)
OPS-MENU RETURN LOCK