User`s manual
Table Of Contents
- Safety Precautions
- Table of contents
- Chapter 1: Outline
- 1-1 Features
- 1-2 Controller
- 1-3 Measurement program
- [1] Positional deviation measurement
- [2] Degree of match inspection
- [3] Lead inspection
- [4] BGA/CSP inspection (IV-S32M/S33M)
- [5] Area measurement by binary conversion
- [6] Object counting by binary conversion
- [7] Object identification by binary conversion
- [8] Point measurements
- [9] Distance and angle measurement
- [10] Multiple position measurement (IV-S33M)
- [11] Multiple degree of match inspection (IV-S33M)
- Chapter 2 : Precautions for Use
- Chapter 3 : System Configuration
- Chapter 4 : Part Names and Functions
- Chapter 5 : Connection and Installation Methods
- Chapter 6 : Setting and Operating Outlines
- Chapter 7 : Simplified Menu Operation
- 7-1 Operation screen
- 7-2 Image display
- 7-3 Setting functions that are different with each controller
- 7-4 Setting procedures
- 7-5 Setting the operation conditions
- 7-6 Setting object types
- 7-7 Setting the shutter speed
- 7-8 Setting the positioning conditions
- 7-9 Setting the existence inspection conditions
- 7-10 Measurement triggering
- 7-11 Saving data
- 7-12 Specify the system conditions
- Chapter 8 : Specifications
- Chapter 9 : Operation Examples
- Glossary
- Appendix
- Alphabetical Index

9-12
Operation Examples (Standard menu: Area measurement by binary conversion)
9
1
REGISTER NO.
0(0~15)
3
1
T.IMG C1 L
1
2
To the next page
(8) Image adjustment
1. Press the SEL key.
- The image taken by camera 1 will be displayed.
- When the image is so bright that the menu display is difficult to see, press the TRG/BRT key to reduce
the brightness of the image. The indicator in the upper right corner of the screen will change from "H"
to "L."
2. To display the image of the object measured clearly, adjust the focus and iris opening of the camera lens
(page 4-1).
3. Press the SEL key to change the screen to the freeze mode.
- The indicator in the upper right corner of the screen will change from T.IMG to F.IMG.
- To set a threshold for a binary area, make sure the machine is displaying the freeze screen.
(For details about the through and freeze modes, see page 7-4.)
4. Press the ESC key to display all of the binary area conditions.
(9) Setting the binary area condition (measurement area)
1. Move the cursor to the "3MEAS AREA" item, and press the SET key.
2. Surround the object to be measured with the measurement area (RECTANGLE: solid line).
- Move the cursor to the "MOVE," "UP.L," or "LO. R," label and press the SET key.
After the position has been finalized, press the SET key.
- After determining each position in the measurement area, press the SET key.
- If the menu overlaps the object to be measured,
so that further image condition setting is
difficult, press the ESC key. Only one item will
be displayed at a time.
- The image shown in the measurement area has
already been through binary conversion.
Continued from the previous page
Press the TRG/BRT key and the
brightness of the screen will change
between L and H.
Indicates that Camera 1 is selected.
Measurement area
Measurement area
Object to be measured
(white)
MOVE The whole rectangle is moved using the up, down, left or right keys (one pixel at a time).
UP.L The upper left corner is moved using the up, down, left or right keys (one pixel at a time).
LO.R The lower right corner is moved using the up, down, left or right keys (one pixel at a time).
①
REGISTER NO.
00(0~15)
②
MEAS SHAPE
RECTANGLE CIRCLE ELLIPSE
③MEAS AREA
MOVE UP.L(224,208) LO.R(287,271)
④
MASK
SHAPE
NO RECTANGLE CIRCLE ELLIPSE
⑤
AUTO REGIST EXEC(L LIMIT ONRY U&L LIMITS)
⑥
THRESHOLD U.LM255 L.LM100(0~255)
⑦
INVERT B/W
NO YES
⑧
BINARY PROCESS FIXED THRESHOLD-ADJ(VAR-DIFF VAR-RATE)
⑨
BINARY NOISE FILT
NO EXPD.→CONTR. CONTR.→EXPD
⑩NUM.OF FILT PASS EXPD.0 CONTR.0(0~5)
OPS-MENU RETURN LOCK EVALUATION