User`s manual
Table Of Contents
- Safety Precautions
- Table of contents
- Chapter 1: Outline
- 1-1 Features
- 1-2 Controller
- 1-3 Measurement program
- [1] Positional deviation measurement
- [2] Degree of match inspection
- [3] Lead inspection
- [4] BGA/CSP inspection (IV-S32M/S33M)
- [5] Area measurement by binary conversion
- [6] Object counting by binary conversion
- [7] Object identification by binary conversion
- [8] Point measurements
- [9] Distance and angle measurement
- [10] Multiple position measurement (IV-S33M)
- [11] Multiple degree of match inspection (IV-S33M)
- Chapter 2 : Precautions for Use
- Chapter 3 : System Configuration
- Chapter 4 : Part Names and Functions
- Chapter 5 : Connection and Installation Methods
- Chapter 6 : Setting and Operating Outlines
- Chapter 7 : Simplified Menu Operation
- 7-1 Operation screen
- 7-2 Image display
- 7-3 Setting functions that are different with each controller
- 7-4 Setting procedures
- 7-5 Setting the operation conditions
- 7-6 Setting object types
- 7-7 Setting the shutter speed
- 7-8 Setting the positioning conditions
- 7-9 Setting the existence inspection conditions
- 7-10 Measurement triggering
- 7-11 Saving data
- 7-12 Specify the system conditions
- Chapter 8 : Specifications
- Chapter 9 : Operation Examples
- Glossary
- Appendix
- Alphabetical Index

9-8
Operation Examples (Simplified menu: Existence inspection)
9
1
5
2
3
5
1
4
6
3THRESHOLD U.LM255 L.LM100(0~255)
4INVERT B/W NO YES
OPS-MENU
L.LM100(0~255)
1REG00 000000~002000
1REG00 000000~002000 A00=001619 OK
2REG01000000~245760 A01=
3REG02000000~245760 A02=
F.IMG C1 L
VX.XX
(TYPE00)
MEAS XXXXms 2000-08-01 10:30
MEASUREMENT1 EXISTENCE
CHG-TYPE EXIST-COND EXIST-EVAL. SEL-CAMERA
OPS-CND SYS-CND ADJ-CONTRAST SAVE SHUTTER
X0~7 Y0~7 READY
①REG00 000000~245760 A00=
②REG01 000000~245760 A01=
③REG02 000000~245760 A02=
④REG03 000000~245760 A03=
⑤REG04 000000~245760 A04=
⑥REG05 000000~245760 A05=
⑦REG06 000000~245760 A06=
⑧REG07 000000~245760 A07=
(7) Setting the binary area conditions (threshold)
1. Move the cursor to the "3THRESHOLD" item using the up and down keys, and press the SET key.
2. Move the cursor to the "L.LM" item with the left and right keys, and then press the SET key.
3. Move the cursor to each digit using the left and right keys, and increase or decrease the values using the
up and down keys.
This cursor will move to the left and right.
- To set the threshold parameters, see the section in the Glossary which describes them.
- After determining the lower limit, press the SET key, and then the ESC key.
4. Move the cursor to the "4INVERT B/W" item using the up
and down keys, and press the SET key.
5. Move the cursor to "YES" using the left and right keys, and
press the SET key.
- Since only the number of white pixels can be measured,
select "YES" if the object is black.
6. Move the cursor to the "OPS-MENU" item using the up and
down keys, and press the SET key.
- The screen will return to the MAIN OPS MENU.
(8) Setting the evaluation conditions
1. Move the cursor to the "EXIST-EVAL." item using the left and right keys, and press the SET key.
- The items 1 to 8 will be displayed.
2. Move the cursor to "1REG00" and press the SET key.
3. Move the cursor to the upper limit position with the left and right keys, and press the SET key.
- Select the digit to change with the left and right keys, and then set the value to 002000 with the up and
down keys.
- After determining the upper limitm value, press the SET key, and then the ESC key.
4. Press the TRG/BRT key.
- The measurement (evaluation) results for item 1 and the image will be displayed.
5. Press "ESC," and move the cursor to the "CHG-TYPE" item using the left and right keys, to confirm that
"Object type number 00" has been selected.
6. Move the cursor away from the "CHG-TYPE" item using the left and right keys.
Inversion: NO Inversion: YES
Object to be measured
Measurement area
Measurement result
Evaluation result
To the next page