User`s manual

Table Of Contents
9-8
Operation Examples (Simplified menu: Existence inspection)
9
1
5
2
3
5
1
4
6
3THRESHOLD U.LM255 L.LM100(0~255)
4INVERT B/W NO YES
OPS-MENU
L.LM100(0~255)
1REG00 000000~002000
1REG00 000000~002000 A00=001619 OK
2REG01000000~245760 A01=
3REG02000000~245760 A02=
F.IMG C1 L
VX.XX
(TYPE00)
MEAS XXXXms 2000-08-01 10:30
MEASUREMENT1 EXISTENCE
CHG-TYPE EXIST-COND EXIST-EVAL. SEL-CAMERA
OPS-CND SYS-CND ADJ-CONTRAST SAVE SHUTTER
X0~7 Y0~7 READY
REG00 000000~245760 A00=
REG01 000000~245760 A01=
REG02 000000~245760 A02=
REG03 000000~245760 A03=
REG04 000000~245760 A04=
REG05 000000~245760 A05=
REG06 000000~245760 A06=
REG07 000000~245760 A07=
 
(7) Setting the binary area conditions (threshold)
1. Move the cursor to the "3THRESHOLD" item using the up and down keys, and press the SET key.
2. Move the cursor to the "L.LM" item with the left and right keys, and then press the SET key.
3. Move the cursor to each digit using the left and right keys, and increase or decrease the values using the
up and down keys.
This cursor will move to the left and right.
- To set the threshold parameters, see the section in the Glossary which describes them.
- After determining the lower limit, press the SET key, and then the ESC key.
4. Move the cursor to the "4INVERT B/W" item using the up
and down keys, and press the SET key.
5. Move the cursor to "YES" using the left and right keys, and
press the SET key.
- Since only the number of white pixels can be measured,
select "YES" if the object is black.
6. Move the cursor to the "OPS-MENU" item using the up and
down keys, and press the SET key.
- The screen will return to the MAIN OPS MENU.
(8) Setting the evaluation conditions
1. Move the cursor to the "EXIST-EVAL." item using the left and right keys, and press the SET key.
- The items 1 to 8 will be displayed.
2. Move the cursor to "1REG00" and press the SET key.
3. Move the cursor to the upper limit position with the left and right keys, and press the SET key.
- Select the digit to change with the left and right keys, and then set the value to 002000 with the up and
down keys.
- After determining the upper limitm value, press the SET key, and then the ESC key.
4. Press the TRG/BRT key.
- The measurement (evaluation) results for item 1 and the image will be displayed.
5. Press "ESC," and move the cursor to the "CHG-TYPE" item using the left and right keys, to confirm that
"Object type number 00" has been selected.
6. Move the cursor away from the "CHG-TYPE" item using the left and right keys.
Inversion: NO Inversion: YES
Object to be measured
Measurement area
Measurement result
Evaluation result
To the next page
Continued from the previous page