User`s manual

Table Of Contents
9-3
9
Operation Examples (Simplified menu: Positioning measurement)
1REG NO 1P-SCH 2P-SCH
5
1
F.IMG C1 L
4
3
1
3
5
2
OPS-MENU
OPS-MENU
Reference image area
Reference image area
Search area
Search area
Press the TRG/BRT key and the
brightness of the screen will change
between L and H.
Indicates that Camera 1 is selected.
To the next page
(5) Image adjustment (1P-SCH is selected in this example)
1. Press the SEL key.
- The image taken by camera 1 will be displayed.
- When the image is so bright that the menu display is difficult to see, press the TRG/BRT key to reduce the
brightness of the image. The indicator in the upper right corner of the screen will change from "H" to "L."
2. To display the image of the object measured clearly, adjust the focus and iris opening of the camera lens
(page 4-1).
3. Move the cursor to the "1REG" line, and press the SET key.
4. Move the cursor to the "1P-SCH" item with the left and right keys, and press the SET key.
- The reference image area and search area will be displayed in the center of the screen.
5. Press the SEL key to change the screen to the freeze mode.
- The indicator in the upper right corner of the screen will change from T to F.
- To register reference images, you must make sure to display the freeze screen.
6. Press the ESC key to display all of the measurement condition items.
(6) Setting the measurement conditions
1. Move the cursor to the "2REF. IMG ARE (MDL 0)" item with the up and down keys, and press the SET key.
2. Surround the object to be measured with the reference image area (solid line).
- Move the cursor to the "MOVE," "UP.L," or "LO. R," label and press the SET key.
After the position has been finalized, press the SET key.
3. Press the ESC key and move the cursor to the "3 SEARCH ARE (MDL 0)" item. Then, press the SET key.
4. Create a search area (dotted line).
- The search area described above is the range for detecting the image registered in step 2, using the gray
scale search function (see the Glossary).
- The procedure for creating the search area is the same as described for the reference image area in step 2.
5. Move the cursor to the "OPS-MENU" item using the up and down keys, and press the SET key.
- The screen will return to the MAIN OPS MENU.
Detected coordinate
(+ part)
- If the menu overlaps the object to be
measured, so that further image condition
setting is difficult, press the ESC key. Only
item 1 will be displayed at a time.
- After the reference image area position has been set,
move the cursor to the "REG." item using the left and right
keys, and press the SET key.
- The stored image will be displayed in the lower right
corner of the screen. After storing the image, press the
ESC key.
- After specifying the search area position, press the ESC key.
Continued from the previous page
MOVE The whole rectangle is moved using the up, down, left or right keys (one pixel at a time).
UP.L The upper left corner is moved using the up, down, left or right keys (one pixel at a time).
LO.R The lower right corner is moved using the up, down, left or right keys (one pixel at a time).
F.IMG C1 L
1REG NO 1P-SCH 2P-SCH
2
REF IMG ARE(MDL0) MOVE UP.L(224,208) LO.R(287,281) CONTRAST SR
REG DISP
3
SEARCH ARE(MDL0) MOVE
UP.L(216,200) LO.R(295,279)