User`s manual
Table Of Contents
- Safety Precautions
- Table of contents
- Chapter 1: Outline
- 1-1 Features
- 1-2 Controller
- 1-3 Measurement program
- [1] Positional deviation measurement
- [2] Degree of match inspection
- [3] Lead inspection
- [4] BGA/CSP inspection (IV-S32M/S33M)
- [5] Area measurement by binary conversion
- [6] Object counting by binary conversion
- [7] Object identification by binary conversion
- [8] Point measurements
- [9] Distance and angle measurement
- [10] Multiple position measurement (IV-S33M)
- [11] Multiple degree of match inspection (IV-S33M)
- Chapter 2 : Precautions for Use
- Chapter 3 : System Configuration
- Chapter 4 : Part Names and Functions
- Chapter 5 : Connection and Installation Methods
- Chapter 6 : Setting and Operating Outlines
- Chapter 7 : Simplified Menu Operation
- 7-1 Operation screen
- 7-2 Image display
- 7-3 Setting functions that are different with each controller
- 7-4 Setting procedures
- 7-5 Setting the operation conditions
- 7-6 Setting object types
- 7-7 Setting the shutter speed
- 7-8 Setting the positioning conditions
- 7-9 Setting the existence inspection conditions
- 7-10 Measurement triggering
- 7-11 Saving data
- 7-12 Specify the system conditions
- Chapter 8 : Specifications
- Chapter 9 : Operation Examples
- Glossary
- Appendix
- Alphabetical Index

9-2
Operation Examples (Simplified menu: Positioning measurement)
9
9-1 Simplified menu
[1] Positioning measurement
The following sections cover an example of how to measure the positioning of the object shown below.
1
1
2
3
[SELECT MENU]
1STANDARD MENU (STD RUN-MENU)
2SIMPLIFIED MENU (SEL EASY MENU)
[SIMPLIFIED MENU]
1MEAS OBJ POSITIONING EXISTENCE
2
SELECT CAMERA
CAM1 CAM1&2
OPS-MENU
To the next page
Object to be measured
1
2
F.IMG C1 L
VX.XX
(TYPE00)
MEAS XXXXms 2000-08-01 10:30
MEASURE0 CAM1 POSITIONING
CHG-TYPE
POSI-COND
POSI-EVAL.
OPS-CND
SYS-CND
ADJ-CONTRAST
SAVE
SHUTTER
X0~7Y0~7 READY
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
56
57
58
59
60
61
62
63
×
×
×
×
×
×
×
×
When the IV-S33M is used
When the IV-S31M is used 00 to 15
When the IV-S32M is used 00 to 31
(1) Power ON
When power is first turned ON after the machine is deliverd, the [SELECT MENU] screen will
appear.
- When the MAIN OPS MENU used by the simplified menus (positioning) is displayed, the
operations covered in steps (2) and (3) are not needed.
- If the MAIN OPS MENU used by the standard menus is displayed, please change to the simplified
menus screen. - See page 6-5.
(2) Select menu
1.Move the cursor to the "2SIMLIFIED MENU" item with the up and down keys, and press the
SET key.
- The [SIMLIFIED MENU] menu screen will appear.
(3) Placing the object to be measured (positioning)
1. Move the cursor to the "1MEAS OBJ" item using the up and down keys, and press the SET
key.
2. Move the cursor to "POSITIONING" using the left and right keys, and press the SET key.
3. Move the cursor to the "OPS-MENU" item using the up and down keys, and press the SET
key.
- The MAIN OPS MENU for setting up positioning measurements will be displayed.
(4) Registration of an object type number (IV-S33M is registered in 00 in this example)
1. Move the cursor to the X next to object type number 00 using the up and down keys. Then
press the SET key.
- The X will change to a circle meaning that object type 00 has been registered.
2. Move the cursor to the "POSI-COND" item using the left and right keys, and press the SET
key.
- The measurement condition setting screen will be displayed.