User`s manual
Table Of Contents
- Safety Precautions
- Table of contents
- Chapter 1: Outline
- 1-1 Features
- 1-2 Controller
- 1-3 Measurement program
- [1] Positional deviation measurement
- [2] Degree of match inspection
- [3] Lead inspection
- [4] BGA/CSP inspection (IV-S32M/S33M)
- [5] Area measurement by binary conversion
- [6] Object counting by binary conversion
- [7] Object identification by binary conversion
- [8] Point measurements
- [9] Distance and angle measurement
- [10] Multiple position measurement (IV-S33M)
- [11] Multiple degree of match inspection (IV-S33M)
- Chapter 2 : Precautions for Use
- Chapter 3 : System Configuration
- Chapter 4 : Part Names and Functions
- Chapter 5 : Connection and Installation Methods
- Chapter 6 : Setting and Operating Outlines
- Chapter 7 : Simplified Menu Operation
- 7-1 Operation screen
- 7-2 Image display
- 7-3 Setting functions that are different with each controller
- 7-4 Setting procedures
- 7-5 Setting the operation conditions
- 7-6 Setting object types
- 7-7 Setting the shutter speed
- 7-8 Setting the positioning conditions
- 7-9 Setting the existence inspection conditions
- 7-10 Measurement triggering
- 7-11 Saving data
- 7-12 Specify the system conditions
- Chapter 8 : Specifications
- Chapter 9 : Operation Examples
- Glossary
- Appendix
- Alphabetical Index

8-7
Specifications
8
8-3 Support tools
[1] Monochrome monitor IV-09MT
Item Speicfications
Power input voltage
Input capacity
Signal voltage
Screen display resolution
Scan method
Scan frequency
Image size
Linearity
Image input connector
Image input impedance
Video output connector
Adjustments
Storage ambient temperature
Operation ambient
temperature
Operation ambient humidity
Atmosphere
Vibration resistance
Shock resistance
Weight
Dimensions (mm)
Dielectric resistance
Insulation resistance
Accessories
90 to 110VAC, 50/60Hz
25 VA
1.0Vp-p/75 ohms
900 scanning lines (center), 600 scanning lines (edges)
EIA 525 lines (2:1 interlaced)
Horizontal : 15.75 kHz, vertical : 48 to 62 Hz
8% under scan
Horizontal : 10% or less, vertical : max. 10%
BNC
75 ohms/ High-Z
BNC
Brightness, contrast, vertical position, horizontal position
Focus, vertical width, horizontal linearity, sub-brightness (only used
by our service staff)
-20 to 60
o
C
0 to 45
o
C
35 to 85 %RH (non-considering)
No corrosive gases
JIS C 0911 or equivalent
- Amplitude 0.15mm, (10 to 57Hz), 9.8m/s
2
(57 to 150Hz),
No. of sweeps : 10 (1 octave/min.) 3 directions (X, Y, Z)
JIS C 0912 or equivalent, 147m/s
2
(3 times each in X,Y, and Z
directions)
Approx. 6 kg
220 (W) × 238 (H) × 257 (D) (not including prorusion)
1000 VAC, 1 minute (between AC plug and shassis)
DC 500VDC, 10M ohms or more (between AC plug and chassis)
One instruction manual
Front
Back
252220
227
238
238
252
11
(Unit : mm)
External dimension drawings