User`s manual
Table Of Contents
- Safety Precautions
- Table of contents
- Chapter 1: Outline
- 1-1 Features
- 1-2 Controller
- 1-3 Measurement program
- [1] Positional deviation measurement
- [2] Degree of match inspection
- [3] Lead inspection
- [4] BGA/CSP inspection (IV-S32M/S33M)
- [5] Area measurement by binary conversion
- [6] Object counting by binary conversion
- [7] Object identification by binary conversion
- [8] Point measurements
- [9] Distance and angle measurement
- [10] Multiple position measurement (IV-S33M)
- [11] Multiple degree of match inspection (IV-S33M)
- Chapter 2 : Precautions for Use
- Chapter 3 : System Configuration
- Chapter 4 : Part Names and Functions
- Chapter 5 : Connection and Installation Methods
- Chapter 6 : Setting and Operating Outlines
- Chapter 7 : Simplified Menu Operation
- 7-1 Operation screen
- 7-2 Image display
- 7-3 Setting functions that are different with each controller
- 7-4 Setting procedures
- 7-5 Setting the operation conditions
- 7-6 Setting object types
- 7-7 Setting the shutter speed
- 7-8 Setting the positioning conditions
- 7-9 Setting the existence inspection conditions
- 7-10 Measurement triggering
- 7-11 Saving data
- 7-12 Specify the system conditions
- Chapter 8 : Specifications
- Chapter 9 : Operation Examples
- Glossary
- Appendix
- Alphabetical Index

7-28
Simplified Menu Operation
7
[2] Specify the computer link conditions
When you want to use computer link communications, you must specify the communication conditions.
- For details about computer link communications, see the IV-S30 User’s Manual (Function and
Operation).
Write address
(max. 512 bytes)
Station No.
Item Setting range
- Sharp: 09000 to 99776
- Mitsubishi: D0000 to D9999
- OMRON: DM0000 to DM9999
- Sharp: 00 to 37
(8) *
- Mitsubishi: 00 to 31
- OMRON: 00 to 31
Only shown when "MITSUBISHI"
is selected in 1 on the
[COMPUTER LINK] menu.
Select either FORM 1 or 4 for the control procedure.
FORM 1 No line terminator
FORM 4 With line terminators: CR + LF
Setting detailsMenu
Select either WW or QW for the block write command.
WW Data writing address range: D0000 to D1023
QW Data writing address range: D000000 to D008191
- In version 2.01, only WW was available.
- In version 2.01, only FORM 1 was available.
5 BLK WRT
COMMAND
4 CONTROL
PROC.
- If "SHARP" or "OMRON" is selected, items 4 and 5 will not be displayed.
On the [SYSTEM COND] menu, move the cursor to item "3 COMPUTER LINK" and press the SET key.
[SYSTEM COND]
1SERIAL OUTPUT NO PC-LINK SERIAL
2COMM.SET
(TO NEXT SUB-MENU)
3
COMPUTER LINK
(TO NEXT SUB-MENU)
[COMPUTER LINK]
1PC MANUFACTURER
SHARP(COMM.PORT LINK-MDL) MITSUBISHI OMRON
2STATION NO. 01
3WRITE TOP ADRS
09000
4CONTROL PROC.
FORM1 FORM4
5
BLK WRT COMMAND
WW
QW
OPS-MENU
RETURN LOCK
* In this manual, octal notation is indicated by
adding(8) after a number.