User`s manual

Table Of Contents
7-25
Simplified Menu Operation
7
7-10 Measurement triggering
[1] Trigger measurement
The IV-S30 has three methods for triggering measurements, as shown below.
1 Using the TRG/BRT key on the remote keypad
2 Triggered by an input terminal (IV-S31M : X0 toX4, IV-S32M : X0 to X5, IV-S33M : X0 to X6)
3 Triggered by a message on the general-purpose serial communication port
(1) Using the TRG/BRT key
1. Select the object type No. that you want to measure on the MAIN OPS MENU. -See page 7-11.
2. Press the TRG/BRT key to start the measurement function. The result will be displayed on the
monitor.
Ë A display example of positioning
Ë A display example of an existence inspection
(2) Triggered by an input terminal
When the measurement start input (input terminal: X0) on the MAIN OPS MENU changes from OFF
to ON, the IV-S30 will start the measurement function. Specify the object type No. that will be
measured on input terminals, (IV-S31M : X1 to X4, IV-S32M : X1 to X5, IV-S33M : X1 to X6) -See
page 5-17 and 5-18.
F.IMG C1 L
VX.XX
(TYPE00)
OK
MEAS XXXXms 2000-08-01 10:30
MEASURE 0 CAM1 POSITIONING
CHG-TYPE POSI-COND POSI-EVAL. SEL-CAMERA
OPS-CND SYS-CND ADJ-CONTRAST SAVE SHUTTER
X0~7 Y0~7
READY
X COORD.(MDL0) 250.0~260.0 X0=253.0 OK
Y COORD.(MDL0) 210.0~230.0 Y0=220.0 OK
MATCH LVL(MDL0)
-10000~+10000 M0=+09620 OK
X COORD.(MDL1) 150.0~160.0 X1=156.0 OK
Y COORD.(MDL1) 055.0~058.0 Y1=056.0 OK
MATCH LVL(MDL1)
-10000~+10000 M1=+09524 OK
 
F.IMG C1 L
VX.XX
(TYPE00)
OK
MEAS XXXXms 2000-08-01 10:30
MEASUREMENT 1 EXISTENCE
CHG-TYPE EXIST-COND EXIST-EVAL. SEL-CAMERA
OPS-CND SYS-CND ADJ-CONTRAST SAVE SHUTTER
X0∼7 Y0∼7 READY
REG00 001600~001650 A00=001619 OK
REG01 000000~245760 A01=
REG02 002600~027000 A02=026720 OK
REG03 000000~245760 A03=
REG04 000000~245760 A04=
REG05 000000~245760 A05=
REG06 000000~245760 A06=
REG07 000000~245760 A07=
 