User`s manual

Table Of Contents
7-23
Simplified Menu Operation
7
[3] Setting the measurement conditions for correcting a position
When the "3 XY CORRECTION" item is set to "YES" on the [SIMPLIFIED MENU] screen, when the
position of the object to be measured is not correct, the correct area can still be measured by correcting
the position.
ËË
ËË
Ë Operating procedure
1. Move the cursor to the "AUX-COND" item on the menu bar of the MAIN OPS MENU, and press
the SET key.
- The screen will change to the measurement condition setting screen.
The following procedures are the same as the 1-point search made for positioning. (See page 7-
14 to 7-16.)
Notes
- Before setting the measurement conditions, make sure to select camera type (when the IV-
S33M is selected : page 7-31), set the object type (page 7-11) and select camera (page 7-5).
Select the same object type No. and Camera No. as were used for the existence inspection
condition settings.
Select "YES" to run the XY correction function.
[SIMPLIFIED MENU]
1MEAS OBJ
POSITIONING EXISTENCE
2
SELECT CAMERA
CAM1 CAM1&2
3
XY CORRECTION
NO YES
OPS-MENU
Repeatedly pressing the
TRG/BRT key on the remote
keypad will toggle the brightness
of the screen between H and L.
Indicates Camera 1.
(Camera 2: C 2)
Repeatedly pressing the SEL key
will switch the screen back and
forth between the F.IMG (freeze
mode) and the T.IMG (through
mode).
When "YES" is selected, a 1-point search is enabled.
1REG NO YES
OPS-MENU
F.IMG C1 H