User`s manual

Table Of Contents
7-20
Simplified Menu Operation
7
5. Press the SEL key to change the screen to the freeze mode.
- The indicator in the upper right corner of the screen will change from T to F.
- To set a threshold for a binary area, make sure the machine is displaying the freeze screen.
6. Press the ESC key to display all of the measurement condition items.
- If the menu overlaps the object to be measured, so that further image condition setting is
difficult, press the ESC key. Only one item "1" will be displayed at a time. (You can move the
cursor to each item and display each of them in order on the screen, using the up and down
keys. The following illustration shows only one item being displayed.)
7. Move the cursor to the "2 MEAS AREA" item, and press the SET key.
8. Place a measurement window around the object to be measured (solid line).
- Move the cursor to the "MOVE," "UP.L" or "LO.R," and press the set key.
-After the window position has been finalized, press the SET key.
9. After the measurement window position is satisfactory, press the SET key.
10. Move the cursor to the "3 THRESHOLD" item using the up and down keys, and press the SET
key.
11. Move the cursor to the "U.LM" or "L.LM" items and then press the SET key.
12. Move the cursor to each digit using the left and right keys, and increase or decrease the values
using the up and down keys. Then, press the SET key.
3THRESHOLD U.LM255 L.LM100(0~255)
OPS-MENU
1REGISTER NO. 0(0~7) NO YES
2MEAS AREA MOVE UP.L(224,208) LO.R(287,271)
3THRESHOLD U.LM255 L.LM100(0~255)
4INVERT B/W NO YES
F.IMG C1 L
OPS-MENU
Measurement window
Object to be measured
2MEAS AREA MOVE UP.L(107,208) LO.R(198,295)
OPS-MENU
MOVE The whole rectangle is moved using the up, down, right or left keys (one pixel at a time).
UP.L The upper left corner is moved using the up, down, right or left keys (one pixel at a time).
LO.R The lower right corner is moved using the up, down, right or left keys (one pixel at a time).