Simplified Menu Operation
7
[1] Setting the measurement conditions
Define the binary measurement area using a rectangular window.
ËË
ËË
Ë Setting procedure
1. Move the cursor to the "EXIST-COND" item on the menu bar of the MAIN OPS MENU, and press
the SET key.
- The screen will change to the measurement condition setting screen.
Note
- Before setting the measurement conditions, make sure to select camera type (when the IV-
S33M is used: page 7-31), set the object type (page 7-11) and select camera (page 7-5).
2. Press the SEL key.
- The image will be displayed. The indicator in the upper right corner of the screen will change
from F (freeze) to T (through).
When the image is so bright that the menu display is difficult to see, press the TRG/BRT key to
reduce the brightness of the image. The indicator in the upper right corner of the screen will
change from "H" to "L."
3. To display the image of the object measured clearly, adjust the focus and iris opening of the
camera lens.
4. Move the cursor to the "1REGISTER NO." line, and press the SET key. Select a register No. (0
to 7) using the up and down keys, and move the cursor to "YES" using the left and right keys.
Then, press the SET key.
- The measurement window will be displayed in the center of the screen.
Measurement window
Object to be measured
1REGISTER NO. 0(0~7) NO YES
OPS-MENU
T.IMG C1 L
Repeatedly pressing the
TRG/BRT key on the remote
keypad will toggle the brightness
of the screen between H and L.
Indicates Camera 1.
Repeatedly pressing the SEL key
will switch the screen back and
forth between the F.IMG (freeze
mode) and the T.IMG (through
mode).
1REGISTER NO. 0(0~7) NO YES
OPS-MENU
F.IMG C1 H