User`s manual
7-14
Setting Examples Using the Set Wizard
7
(5) Move the cursor to " STANDARD WIZARD" and press the SET key. The set wizard will start.
= In this example, the settings on the screens from the STEP1 to STEP 3 (CORRECT POSITION)
are not changed. Select "NEXT" on each of these screens to go to the next screen. =
(6) Select a camera in order to specify measurement
conditions
Move the cursor to " CAM1" or " CAM2" using
the up and down arrow keys, and press the SET
key.
Note: If you select "NO REGISTRATION", you
cannot set the measurement conditions.
How to go to next step while leaving the current step in
the Set Wizard unchanged.
(1) Press the up or down arrow key several times to move
the cursor to the "NEXT" item.
(2) Press the SET key.
STEP1
SELECT THE MEASUREMENT
START INPUT I/F
1
PARALLEL+SERIAL+USB
■
2
TRIG CCD START
□
NEXT DETAIL
STEP2
SELECT AN IMAGE CAPTURING
METHOD DURING OPERATION
1
PARTIAL-IMG
■
2
ALL IMAGE
□
3
NO CAPTURED
□
ENTER A SHUTTER SPEED
(1/30∼1/10000)
1
SHUTTER SPEED 1/00060
RETURN NEXT
STEP1
SELECT THE MEASUREMENT
START INPUT I/F
1
PARALLEL+SERIAL+USB
■
2
TRIG CCD START
□
NEXT DETAIL
STEP3
CORRECT POSITION?
1
NO
■
2
CAM1
□
3
CAM2
□
RETURN NEXT
This screen is used to select the
signal that the system will use to start
making a measurement.
The default is
"1PARARELL+SERIAL+USB."
- For details, see page 21-1 in
Function and Operation.
CCD trigger
- For details, see page G-2.
Select a method to capture image.
The default is "1PARTIAL-IMG."
Specify whether or not to correct the
captured image.
- For details, see page 3-42 in
Function and Operation.
STEP3
SELECT A CAMERA TO SPECIFY
MEASUREMENT CONDITIONS
1
NO REGISTRATION
□
2
CAM1
■
3
CAM2
□
RETURN NEXT
TYPE00
Start
STEP1:PARALLEL+SERIAL+USB
STEP2:
CAPTURE IMG/PARTIAL-IMG
STEP3:MEAS1/CAM1
End
COLOR F C1 BRTSET WIZARD EXIT