User`s manual

7-9
Setting Examples Using the Set Wizard
7
(11) Select whether or not to set the evaluation
conditions for measured results.
Select " YES" and press the SET key.
The "DETAIL" item will appear on the lower part
of the screen. Move the cursor to "DETAIL" and
press the SET key.
The "EVALUAT COND" screen will appear.
Select " REGISTER NO." using the up and
down arrow keys. Change the number to "0"
using the up and down arrow keys. Then press
the SET key.
Select " CONDITION SET," " DEG-MATCH
OF COL," using the up and down arrow keys,
and enter upper and lower limit values. Use the
left and right arrow keys to change between
each digit and use up and down arrow keys to
change values of each digit.
Select a digit using the left and right arrow keys.
Select a number using the up and down arrow
keys. For example, when selecting " DEG-
MATCH OF COL," determine values, and then
press the SET key. Then move the cursor to
"NO" on the "OUTPUT" column using the left
and right arrow keys.
After the value is correct, press the SET key.
Then press the left and right keys to move the
cursor to "OUTPUT." Now press the SET key. A
popup menu will appear and you can choose
"NO," "Y," or "C."
Note: "Y" is for terminal block. "C" is for auxiliary
relay.
Move the cursor to "Y" and press the SET key. Then select the Y0 and press the SET key. Now
the evaluation results will be output to the Y0 terminal.
For details about the evaluation conditions, see page 3-28 in Function and Operation.
After the settings are complete, press the ESC key to return to the "SET WIZARD" screen.
1
REGISTER NO
0 (07)
[TEST RESULT] [OOUTPUT]
2
CONDITION SET AUTO (–10%)
3
AREA
000000245760
A = NO
4
HUE (AVG)
000. 0 359. 9
H = NO
5
CHROMA (AVG)
000. 0 255. 0
S= NO
6
DEG-MATCH OF COL
-10000+10000
CM= NO
7
TEST EXEC (WITH-POSI. ADJ WITHOUT-POSI. ADJ)
COLOR F C1 BRT
EVALUAT COND SCREEN COND SAVE EDIT SEL
1
REGISTER NO
0 (07)
[TEST RESULT] [OOUTPUT]
2
CONDITION SET AUTO (–10%)
3
AREA
000000245760
A = NO
4
HUE (AVG)
000. 0 359. 9
H = NO
5
CHROMA (AVG)
000. 0 255. 0
S= NO
6
DEG-MA
7
TEST
SET=VALUE INPUT ESC=BACK SEL=CHNG IMG TRG=FUNC
COLOR F C1 BRT
EVALUAT COND SCREEN COND SAVE EDIT SEL
Y OUTPUT
Y0
Y1
Y2
Y3
Y4
Y5
Y6
Y7
Use place SI. AD
NO
NO
NO
NO
NO
NO
NO
NO
NO
Y
C
STEP7
COMPARE EVALUATION
CONDITIONS TO MEASUREMENT
RESULTS (YES/NO)
1
NO
2
YES
RETURN NEXT DETAIL
TYPE00
Start
STEP1PARALLEL+SERIAL+USB
STEP2CAPTURE IMG/PARTIAL-IMG
STEP3MEAS1/CAM1
STEP4MEAS1/P/COLOR EVALUATION
STEP5MEAS1/WINDOW/NORMAL
STEP6MEAS1/MEAS CND
STEP7MEAS1/EVALUATION
End
COLOR F C1 BRTSET WIZARD EXIT
[SAMPLE]