User`s manual
6-8
Setting and Operating Outlines
6
6-4 Operation chart
As each setting is made using the wizard, the operation chart keeps track
of the settings and displays them as an operation chart. You can see all
settings you have made so far, or jump back to a specific step on the
operation chart.
This section describes how to use the operation chart. The operation chart
shows the measurement decisions that were made and saved as a chart.
You can easily see the major flow of the measurement process and you
can determine the execution timing for processes other than image
processing (such as numeric and ladder processing). Also, you can
change the settings for each step.
[1] Method for displaying the operation chart
1. Move the cursor to "MAIN-COND" at the bottom of
the operation screen and press the SET key.
2. The "MAIN MENU" will appear.
Move the cursor to "SET WIZARD" using the up
and down arrow keys, and press the SET key.
3. The "SET WIZARD" screen will appear.
X0∼7
□□□□□□□□
Y0∼7
□□□□□□□□
READY
■
MNU-CHG MAIN-COND CHG-MEA COND-CHG CHNG-REG SCREEN-CHG CHG-TYPE
(
TYPE00
)
V*.**
MEAS 0000ms 2001-10-14 10:38
MEASURE 0 CAM1 NO
COLOR F C1 BRT
Choose this
SCREEN SAVE DEL
COLOR F C1 BRTSET WIZARD
[
SAMPLE
]
1
CHG-TYPE
2
STANDARD WIZARD
3
OPERATION CHART
TYPE00
Start
End
TYPE00
Start
STEP1:PARALLEL+SERIAL+USB
STEP2:CAPTURE IMG/PARTIAL-IMG
STEP3:COLOR IMAGE CORRECT
STEP4:MEAS1/CAM1
STEP5:MEAS1/F/BIN-AREA
STEP6:MEAS1/WINDOW/MASK,1
STEP7:MEAS1/MEAS CND
STEP8:MEAS1/EVALUATION
STEP9:MEAS1/CALC
STEP10:MEAS1/OUT
STEP11:FINAL NUMERIC CALC
STEP12:FINAL OUTPUT COND
STEP13:SERIAL OUTPUT/ANY
STEP14:OPS MENU COND
STEP15:CALIBRATION/YES
STEP16:MOVE ALL WINDOW/YES
STEP17:TITLE/YES
End
COLOR F C1 BRTMAIN MENU
IVC35M
SYS-CND
OBJECT TYPE COND
SET WIZARD
EDIT MAIN OPS MENU
OPTION
ENVIRONMENT SETTING
MEMORY CARD