User`s manual

5-12
5
Connection and Installation Methods
X5 X6 X7X2X1 X4X0 X3
Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7
COM
READY
COM
Output terminals (OUTPUT)
Input terminals (INPUT)
Terminal
block
Interrupt processing input
(1 terminal)
External trigger (X0)
Input (7 terminals)
Object type change (X1 to 5): 5 terminals
External input (X6 and 7): 2 terminals
Common for input (1 terminal) (+) or (-) common
Output (9 terminals)
READY: 1 terminal
Logical output set by user (Y0 to 7): 8 terminals
Common for output (1 terminal) (+) or (-) common
Power supply (2 terminals) 24 VDC: 1 terminal, 0 V: 1 terminal
[4] Connecting to the input/output terminals (parallel I/F)
8 input terminals and 9 output terminals are available on the input/output terminal block on the
controller (IV-C35M).
The input terminal block has INPUT terminals X0 to X7 and COM , and the output terminal block has
OUTPUT terminals Y0 to Y7, READY and COM .
Input/output terminal block on the controller
I/O port
The input/output terminals are isolated by photocouplers, to prevent malfunctions due to noise. Use
them within the rated range. The specifications of the input/output ports are listed below.
12/24 VDC
10.8 to 26.4 VDC
ON: 10.5 V or less OFF: 5 V or more
ON: 3 mA or less OFF: 1.5 mA or more
3.3 k ohm
1 ms or less (OFF to ON, ON to OFF)
12/24 VDC
10.8 to 26.4 VDC
100 mA DC
MOS FET open drain
1.2V or less (100mA)
Photo MOS isolation
3 ms or less (OFF to ON, ON to OFF)
Rated input voltage
Input voltage range
Input voltage level
Input current level
Input impedance
Response time
Rated output voltage
Load voltage range
Rated max. output current
Output type
Drop of ON voltage
Isolation method
Response time
Input
Item Rating
Output