User`s manual

3-4
System Configuration
3
(3) When a personal computer is connected
- Purpose/application
Measurement is started by a CCD trigger (sampling start input: personal computer), and the
measurement data is output to a personal computer. The object type number is selected by the
personal computer.
[2] System configuration example for measurement triggered by the internal CCD
sensor trigger
The internal CCD trigger can be used with camera 1, but with camera 2.
(1) When IV-C35M is used in a stand-alone mode
- Purpose/application
Measurement is started by a CCD trigger, and the measurement result is output externally
(warning lamp etc.). In this case, sampling operation is automatically started.
External trigger
(a photo sensor or proximity
sensor etc.)
Controller
IV-S3
M
OUTPUT
INPUT
POWER
Y7Y0 Y1 Y2 Y3 Y4 Y5 Y6
COM
COM
24V
X7X0 X1 X2 X3 X4 X5 X6
READY
0V
VIDEO
CAMERA1
CAMERA2
USB
RS232C/RS422
REMOTE
Personal
computer
Power supply
(24 VDC)
Monitor
Camera 1 (image)
Camera 2 (image)
Measurement data
Object type
change signal
Controller
IV-S3M
OUTPUT
INPUT
POWER
Y7Y0 Y1 Y2 Y3 Y4 Y5 Y6
COM
COM
24V
X7X0 X1 X2 X3 X4 X5 X6
READY
0V
VIDEO
CAMERA1
CAMERA2
USB
RS232C/RS422
REMOTE
Remote keypad
Camera 1 (image + CCD trigger)
Camera 2 (image)
Power supply (24 VDC)
Monitor
External
output