User`s manual
1-15
1
Outline
(3) Count objects by binary conversion
(4) Distance and angle measurement
This measurement setting screen can be accessed from the measurement condition setting
screen of the positional deviation measurement, degree of match inspection, object identification
by binary conversion (gravity center measurement: Yes), multiple position measurement, and
multiple degree of match inspection.
- Inspection procedure
Capture image
Measure (quantity, total area size)
Pill
Purpose
Example
Application
Count the number of separate colored areas on a workpiece that were extracted
color or with a color emphasized by using a color filter.
Inspecting LED lighting indication on mobile phones, missing pills on sheets.
Measurement area
[Measurement result]
- Number of workpieces/total
area size
Color extraction
(binary conversion)
Search area
(criterion image a)
Search area
(criterion image b)
Criterion image b
Criterion image a
Example
Application Measurement of mounted electronic parts
Purpose
Measure the distance and angle of two points using the center detection function in a
gray scale search and the edge detection function, as well as center of gravity
detection by functions.
- This function can measure the following distances and angles: distance between
two points, X coordinate distance, Y coordinate distance, the angle between three
points, the horizontal angle of two points, and the vertical angle of two points.
- The following points and lines can be set: center point, circle center point, gravity
center, point where two straight lines cross, and line passing through two points.
● Measuring IC packages
Register criterion image a and b by matching edges of the IC package.
- Measurement procedures
1 Find the center points of criterion images a and b using a 2-point gray scale
search.
2 Determine the distance between the two center points.