User`s manual

7-30
Setting Examples Using the Set Wizard
7
The "EVALUAT COND" screen will appear.
Select " REGISTER NO." using the up and
down arrow keys. Change the number to "0"
using the up and down arrow keys. Then press
the SET key.
Select " CONDITION SET," " x DEVIATE,"
and " y DEVIATE" using the up and down arrow
keys, and enter upper and lower limit values. Use
the left and right arrow keys to change between
each digit and use up and down arrow keys to
change values of each digit.
For example, when selecting " x DEVIATE" or
" y DEVIATE," press the SET key and then
move the cursor to the "OUTPUT" column using
the left and right arrow keys. Now, press the SET
key, a popup menu appears. From this popup
menu, select output destination from "NO," "Y,"
and "C."
Move the cursor to "Y" and press the SET key.
Then select the Y0 and press the SET key. Now
the evaluation results will be output to the Y0
terminal.
* In this example, select output Y0 for " x
DEVIAT" and output Y1 for " y DEVIAT."
For details about the evaluation conditions, see page 3-28 in Function and Operation.
After the settings are complete, press the ESC key to return to the "SET WIZARD" screen.
SCREEN COND SAVE EDIT SEL
RED F C1 BRT
EVALUAT COND
SEL=VALUE INPUT ESC=BACK SEL=CHNG IMG TRG=FUNC
1
REGISTER NO. 0(0~7)
[
TEST RESULT
][
OUTPUT
]
2
CONDITION SET AUTO(–10%)
3
X COORD. (MDL0)000.0511.0 X0= NO
4
Y COORD. (MDL0)000.0479.0 Y0= NO
5
x DEVIATE (MDL0)-511.0∼+511.0 x0= NO
6
y DEVIATE (MDL0)-479.0-479.0 y0= NO
7
MATCH LVL (MDL0)-10000+10000 M0= NO
8
TEST EXEC(WITH-POSI.ADJ WITHOUT-POSI.ADJ)
SCREEN COND SAVE EDIT SEL RED F C1 BRTEVALUAT COND
SEL=VALUE INPUT ESC=BACK SEL=CHNG IMG TRG=FUNC
1
REGISTER NO. 0(0~7)
[
TEST RESULT
][
OUTPUT
]
2
CONDITION SET AUTO(–10%)
3
X COORD. (MDL0)000.0511.0 X0= NO
4
Y COORD. (MDL0)000.0479.0 Y0= NO
5
x DEVIATE (MDL0)-511.0∼+511.0 x0= NO
6
y DEVIATE (MDL0)-479.0-479.0 y0= NO
7
MATCH LVL M
0
=
8
TEST EXEC(WITH-POSI.ADJ WITHO
Y OUTPUT Use place
Y0
NO
Y1
NO
Y2
NO
Y3
NO
Y4
NO
Y5
NO
Y6
NO
Y7
NO
NO
Y
C