User`s manual

1-31
Setting and Operating Outline
1
External interface
Terminal block
Item
Specifications
Parallel interface Input: 8 points, Output: 9 points, 12/24 VDC
General-purpose serial
interface
RS232C/RS422 (2.4 to 115.2 kbps)
Computer link
Built-in compatibility with certain SHARP, OMRON, Mitsubishi and
Yokogawa models
USB
USB device node (Compatible with USB1.1)
Image output
1 channel, Equivalent to NTSC system, 2:1 interlace
Number of cameras Maximum of 2
Connecting camera IV-C30C5, IV-S30C3, IV-S30C4
Make settings
Using the IV-S30RK1 remote keypad and/or the IV-S30SP parameter
setting support software
Measurement
start input
Internal trigger Color CCD trigger, (Gray) CCD trigger
External trigger
Trigger input (parallel I/F), general-purpose serial I/F, keypad trigger (for
manual measuring)
Inputs
Number of points
8 points: External trigger; 1 point (X0), Object type change; 5 points (X1 to
X5), external input; 2 points (X6, X7)
Common terminal 1 point: + or - common
Outputs
Number of points 9 points: 1 READY,8user settable logical outputs (Y0 to Y7)
Common terminal
1 point: + or - common
Power
supply
Power supply
terminal
2 points: +24 VDC, 0 V
Power supply voltage 24 VDC (±10%)
Power consumption 12 W
Storage ambient temperature -20 to 70
o
C
Operation ambient temperature 0 to 45
o
C
Operation ambient humidity 35 to 85% RH (non-condensing)
Operation atmosphere No corrosive gases or dust
Vibration resistance JIS C 0911 or equivalent
Shock resistance JIS C 0912 or equivalent
Noise immunity
1000 Vp-p 1ms width impulse (by noise simulator) when applied to the
primary side (100 VAC) of an external DC power supply
Outside dimensions 130 (W) · 100 (D) · 42 (H) mm (except protruding portions)
Weight Approx. 600 g