User`s manual
22-15
Communication (General Purpose Serial Interface)
22
Ë
Response
:
70
Ë Command
SC
(H)
SC
(L)
CR
Read the
manual
measurement
coordinates
70
Process
code
Process function
Communication format
Set the manual
measurement
coordinates
71
Ë
Response
Ë Command
:
70
1
SC
(H)
SC
(L)
CR
Station
No.
:
71
SC
(H)
SC
(L)
CR
RC
(H)
RC
(L)
RC
(H)
RC
(L)
Station
No.
Station
No.
2 3 4
:
71
1
SC
(H)
SC
(L)
CR
Station
No.
2 3 4
1 → X coordinate (000 to IFF
(H)
) of the cursor 1
: 0 to 511
2 → Y coordinate (000 to IDF
(H)
) of the cursor 1
: 0 to 479
3 → X coordinate (000 to IFF
(H)
) of the cursor 2
: 0 to 511
4 → Y coordinate (000 to IDF
(H)
) of the cursor 2
: 0 to 479
1 → X coordinate (000 to IFF
(H)
) of the cursor 1
: 0 to 511
2 → Y coordinate (000 to IDF
(H)
) of the cursor 1
: 0 to 479
3 → X coordinate (000 to IFF
(H)
) of the cursor 2
: 0 to 511
4 → Y coordinate (000 to IDF
(H)
) of the cursor 2
: 0 to 479
Ë Command
Ë
Response
Reset
69
:
69
SC
(H)
SC
(L)
CR
:69SC SC
(L)
CR
RC
(H)
RC
(L)
(H)
Station
No.
Station
No.