User`s manual

20-7
PC Function
20
H
D
B
N
C
Auxiliary
Distance
Angle
Numerical calculation results
Auxiliary relay
00H to 15H
00D to 15D
00B to 15B
N0 to N15
C000 to C127
Distance and angle measurement *
Symbol
Kind of input
* The measurement programs that can use these inputs are the positional deviation measurement,
degree of match measurement, object identification by binary conversion (center of gravity: YES)
multiple positional measurement, and
multiple degree of match inspections
.
Kind of input
Measurement program
Symbol
Multiple positions measurement
Multiple degree of match inspections
Number of objects
Auxiliary relay
0K to 3K
N0 to N15
0K to 3K
N0 to N15
Numerical calculation
results
K
N
C C000 to C127
Input types Symbol
Measurement
program
Fault inspection
Max. density difference SG 00SG to 07SG
Max. density MXG 00MXG to 07MXG
Min. density MNG 00MNG to 07MNG
Numerical calculation
result
NC N0 to N15
Auxiliary relay C C000 to C127
Input types Symbol
Measurement program
Color
evaluation
Color unevenness
inspection
Total area A 0A to 7A 0A to 7A
Number of objects K 0K to 3K
Area of each label R
0R000 to 0R127
...3R000 to 3R127
Hue H 0H to7H 0Hto3H
Hue fault EH 00EH to 03EH
Saturation S 0S to 7S 0S to 3S
Saturation (chroma)
fault
ES 00ES to 03ES
Color degree of match CM 00CM to 07CM
Numerical calculation
result
NN0toN15 N0 to N15
Auxiliary relay C C000 to C127 C000 to C127