User`s manual
13-7
Color Positional Measurement
13
DETECT CRD (detection coordinates)
Select whether to use the detection coordinates
as the center of the reference area or to allow
the point to be set freely.
Note: This item is not displayed unless
"REFERENCE IMAGE" is selected on
"DETAIL" on the upper function menu.
See page 5-4.
*If you are selecting a 2-point search, also set
the points the same way as for MDL2.
[2] Setting the register conditions for edge detection
This paragraph describes setting procedures when the mode (see page 13-3) is set to "1-PNT EDGE."
REFERENCE COLOR
Select a reference color for color extraction from
the already registered colors (when more than
two colors are registered).
SEARCH AREA
Select " SEARCH AREA (MDL0)" and press
the SET key to go to the setting screen.
When a rectangle is selected
Highlight " UP.L" and press the SET key. The
X and Y axes will appear in the detection area.
Move the X/Y axes using the up/down/left/right
arrow keys to identify the upper left corner.
When correct, press the SET key.
- As for setting of a pattern that will be used for
image processing, see pages 3-15 to 3-19.
- To return to the previous coordinates, press
the ESC key.
Next, highlight " LO.R" and press the SET key.
Identify the lower right corner the same way.
1
REGISTER NO. 0 (0∼7)
2
COLOR DETECT 0 (0∼7)
3
MEAS SHAPE (MDL 0) RECTANGLE
4
REFIMG ARE (MDL 0) SET (224, 208)∼(287, 271)
5
SEARCH ARE (MDL 0) SET (216, 200)∼(295, 279)
6
REFIMG (MDL 0) 000 (000∼000)
7
DETECT CRD (MDL 0) CENTER (255, 239)
SET=VALUE INPUT ESC=BACK SEL=CHNG IMG TRG=FUNC
COLOR F C1 BRT
REG CND SCREEN COND SAVE DETAIL
■REFERENCE IMG
■DETECT CRD
CENTER
MANUAL
MDL 0
1
UP. L
(224, 208)
2
LO. R
(287, 271)
3
MOVE
SET=MOVE ESC=BACK SEL=CHNG IMG TRG=FUNC
COLOR F C1 BRT
RECTANGLE RESET RETURN
X:224 Y:208
1
REGISTER NO. 0 (0∼7)
2
COLOR DETECT 0 (0∼7)
3
MEAS SHAPE (MDL 0) RECTANGLE (NO ARTF)
4
REFIMG ARE (MDL 0) SET (224, 208)∼(287, 271)
5
DTECT MODE (MDL 0) CHNG POINT
6
SEARCH DIR (MDL 0) HORIZ (→)
7
THRESHOLD (MDL 0) 04 (1∼16)
8
REF COORD (MDL 0) SET KEY (512, 480)
SET=VALUE INPUT ESC=BACK SEL=CHNG IMG TRG=FUNC
COLOR F C1 BRT
REG CND SCREEN COND SAVE