Version 1.0 Produced in Jan. 2004 Instruction Manual LCD monitor IV-08MP Thank you for purchasing the SHARP IV-08MP LCD monitor. Read this introductory instruction manual carefully to thoroughly familiarize yourself with the functions and proper procedures for operation. Notes • This manual was written with the utmost care. However, if you have any question or inquiries concerning the product, please feel free to contact our dealers or service agents. • Copying all or part of this booklet is prohibited.
Components of IV-08MP The components of IV-08MP are as follows.
Safety Precautions Read this instruction manual and the attached documents carefully before installing, operating, or performing any maintenance, in order to keep the machine working correctly. Make sure you understand all of the equipment details, safety information, and cautions before using this machine. In this user's manual, the safety precautions are categorized as "Caution". Caution : Improper handling may cause dangerous situation, moderate or light injury, or damage to equipment.
1. Outline/ Features This touch panel type 8.4-inch TFT color LCD monitor , the IV-08MP, realizes power saving, automation and cost saving in inspection/measurement processes as the monitor for image sensor in various arenas. Using LCD with high-brightness and wide viewing angle, this monitor which is thinner and smaller than CRT can be easily mounted to the equipment. The touch panel provides a function to enter various settings to the controller (IV-S51M) by simply touching the screen.
2. Precautions for Use Pay attention to the points below when handling the IV-08MP. (1) Installed location and environment • Use the equipment in the environment where the ambient temperature is 0~40°C and the relative humidity is less than 90% RH. If the ambient temperature is out of the above range, install a forced fan or an air conditioner to keep the temperature within the required range.
3. System Configuration IV-S50 series controller can be directly connected to the backside of the IV-08MP monitor and used as one unit. IV-08MP can also be connected to the controller using the monitor cable.
4.
Name Function TFT LCD panel (Touch panel) LCD panel with 800×600 dots display. The stylus pen or a finger is used to enter the operation by directly touching the screen. Stylus pen This pen is used to enter the operation by touching the touch panel. Power lamp When the equipment is energized, it will be lit. Power supply input terminal Commercially available constant-voltage power supply (24V DC±10%) is connected here.
5. Installation Method [1] Installation of IV-08MP Secure the IV-08MP using four (4) mounting holes of the main housing angle brackets (four (4): provided with the equipment). Cut out the panel ( 228.0+0.50 × 186.0 +0.50 mm) of the mounting surface (thickness: max.7 mm) to fit the IV-08MP into the surface. (When mounting the main unit only) .7 mm x Ma Mounting surface Mounting holes of the main housing angle brackets (total 4 locations including the lower part) 22 8 +0 . 0 5 200.0mm mm 186 +0.
(When directly connected to the controller) .7 mm x Ma Mounting surface Mounting holes of the main housing angle brackets (total 4 locations including the lower part) 22 8 +0 . 0 5 186 +0.5 0 mm IV-08MP 200.0mm mm 24 2.0 mm Dimensions of the cut panel The dimensions of the cut panel will be the same in either case where only the main unit is mounted or directly connected to the controller. 186 +0.5 0 mm 228 +0.
Insert four (4) main housing angle brackets (2 each at upper and lower) into the mounting holes of the IV-08MP, and secure the IV-08MP to the mounting area with champing screws of the main housing angle. Max. 7 Mounting area Waterproofed gasket Tightening torque: 0.3 ~ 0.4Nm (unite: mm) Attachment fitting Champing screw When properly secured 0 when secured 5.1 17.6 29.6 65.65 14.55 46.
External dimensions (main housing) 7.5 227 113.5 74.2 3.5 24.5 5.1 12.5 41 14.3 24.5 113.5 242 5.1 121 41 1.3 24.5 5.1 51.1 12.5 41.5 1.4 13 25.24 12.38 11 25.24 74.2 (A view on arrow) 5-4 12.38 185 92.5 46.1 51.1 65.65 5 7.5 14.55 1.4 5 13 100 12.5 POWER 24.5 12.5 81.5 41.5 200 12.5 92.5 100 5 121 7.5 7.
External dimensions (When directly connected to the controller) 242 IV−S51M POWER FG +24V USB +0V Y0 COM Y1 Y2 Y3 USB Y4 Y5 TERMINATOR Y6 LINK Y7 Y8 Y9 Y11 LAN EXP Y12 200 Y10 RX ANALOG RGB Y13 Y14 Y15 RDY C(−) A CAMERA1 X0 X1 X2 X3 X4 IV MONITOR ONLY X5 X6 CAMERA2 X7 X8 X9 X10 X11 X12 X13 X14 X15 C(+) POWER 5 100.7 29.6 46.1 14.55 30.3 85.3 126.4 IV CONTROLLER ONLY SER.NO. SHARP MANUFACTURING SYSTEMS CORPORATION MADE IN JAPAN FG 0V 24V (A view on arrow) 5-5 100.
6. Connection Method [1] Connecting to the controller (IV-S51M) When the controller (IV-S51M) is directly connected, follow the instruction below to connect the controller to the IV-08MP. (1) When directly connected Remove the connector cover from the main housing of IV-S51M. Connector cover Fit the tab A of the IV-08MP in the notch part of the IV-S51M. Tab A To connect them, press the IV-S51M in place in the direction of the arrow so that the tab B is fit into the notch part.
Insert two (2) main housing angle brackets (supplied with IV-08MP) as indicated below and secure them with two (2) securing screws (supplied with IV-08MP). Main housing angle brackets (2) When IV-08MP is connected to the controller using the monitor cable Connect the monitor output connector of the IV-S51M and the monitor input connector of the IV08MP using the IV monitor cable (IV-S50MC2).
[2] Connecting to a power supply Connecting a commercially available constant-voltage power supply to the power terminal (POWER: +24V, 0 V) on the IV-08MP. Use a 24V DC±10%, 800mA or more constant-voltage power supply. • Use an individual power supply to supply power to the IV-08MP. • Check the polarity of the power supply terminals, +24 V and 0 V. If power is supplied with the polarity inverted, the failure of the IV-08MP may occur. FG 0V 24V This distance must be as short as possible.
7. Specifications (1) General specifications Item Power supply Power consumption Specifications 24V DC, ±10% 12W Storage ambient temperature -20 to 60°C Operation ambient temperature 0 to 40°C Operation ambient humidity 35 to 95% RH (no condensation) Atmosphere No corrosive gasses Vibration resistance JIS B 3502 or equivalent Vibration and acceleration: 0.15mm (10 ~ 58Hz), 9.8m/s2 (58 ~ 150Hz) Vibration frequency: 10 ~ 150 ~ 10Hz (1oct/min.