Technical data
44
©
FuG Elektronik GmbH, D-83135 Schechen, Am Eschengrund 11
http://www.fug-elektronik.de, E-Mail: info@fug-elektronik.de
V 0913
Options and modifications:
Analog programming
Analog programming:
With this option the output volt-
age and current of the power
supply can be set via analog
voltages (0-10V) or by external
potentiometers. Monitor signals
of voltage and current (0-10V)
available on the programming
terminal. An external "ON"-
command enables the regula-
tion loop.
Selection of manual operation
or external programming is pos-
sible by a switch on the front
panel. This option is also availa-
Many FuG- power supplies are
available which differ from the
standard design or equipment.
On this pages we highlight
some of the most common
options and modifications. Oth-
er customer-specific units hav-
ing different technical data,
different mechanical construc-
tion, alternative customer de-
fined interfaces or with extend-
ed features are available even
for single piece orders.
ble as a retrofit set for later up
gradation of your unit.
Usually the "0V" of the pro-
gramming voltage is connected
to one of the outputs of the unit.
If this is not wanted, the unit
may be equipped with floating
analog programming.
For this version:
Isolation max. 2kV DC with
respect to the unit output,
30V DC with respect to
ground.
On request we can also supply
a fibre optic option with isolation
capabilities up to 200kV and
more.
For most models, the floating
analog programming can be
installed later at our site.
Pin Configuration: SUB-D 15 pin (Solder side of the plug )
Pin Description Comment
1 Status report: current regulation regulation activ e ≙ approx . +15V v ia 10kW
2 Status report: v oltage regulation regulation activ e ≙ approx . +15V v ia 10kW
3 Monitor-signal current
0…nominal v alue ≙ 0...+10V; Ri = 10kW
(alw ay s positive, independent of output polarity)
4 Slider front plate v oltage potentiometer
0...+10V depending from position of potentiomer knob
(not used with isolated analogue programming)
5 Slider front plate current potentiometer
0...+10V depending from position of potentiomer knob
(not used with isolated analogue programming)
6 0V for digital signals
7
Polarity change for units w ith electronic polarity rev ersal
(otherw ise not used)
open = positiv e
connected to 6) = negativ e
8 Set v alue v oltage 0...+10V ≙ 0…nominal v alue
9 0Vfor analogue signals
10 + 10 V reference w ith reference to pin 9; load up to approx . 2mA
11 Monitor-signal v oltage
0…nominal v alue ≙ 0...+10V; Ri = 10kW
(alw ay s positive, independent of output polarity)
12 Command: „output ON / OFF“ open = OFF
connected to pin 6 = ON
no mains interruption!
13
Polarity signalization for units w ith electronic polarity rev ersal
(otherw ise not used)
+12V = positiv e
0V = negativ e
14 not used
15 Set value current 0...+10V ≙ 0…nominal v alue
For single types of equipments, deviations from this configuration are possible (especially for HCN7E, HCB, NLB and custom-designed equip-
ment). In these cases the equipment description is valid.
For proper function of the analog programming at least pin 12 (Output ON/OFF - link to 0V) and both pins 8 and 15 (set values ≠ 0) have to be
connected. Using external set value signals, the "0V" line also has to be connected.
On request we also deliver a complete remote control with indicating instruments and set-point potentiometers in a separate case (cable length to
10m), matching to the analog programming.