Technical data

43
©
FuG Elektronik GmbH, D-83135 Schechen, Am Eschengrund 11
http://www.fug-elektronik.de, E-Mail: info@fug-elektronik.de
V 0913
Technical Appendix
Mains Fuses, Connected Wattage
For design of your electricity
supply please provide the next
higher rated value of the main
fuses used inside the unit. For
external fuses use such with
delayed action. When circuit
breakers are used, we recom-
mend “G” or ”K” characteristic.
Type Range Power Class [W] Voltage Range Efficiency Mains Fuse
(Automaten)
4.200
6,5V upto20V 25A
7.000 6,5V upto 20V 25A
10.500 6,5V upto20V 32A
14.000
6,5V upto 20V 32A
21.000 6,5V upto20V 50A
28.000 6,5V upto 20V 80A
35.000 6,5V upto20V 80A
50.000
6,5V upto 20V 160A
4.200
35V upto 350V 25A
7.000 35V upto 350V 25A
10.500 35V upto 350V 32A
14.000 35V upto 350V 32A
21.000 35V upto 350V 63A
28.000 35V upto 350V 100A
35.000
35V upto 350V 80A
50.000
35V upto 350V 160A
7.000
All 20A
10.500 All 25A
14.000
All 50A
21.000 All 50A
28.000 All 63A
35.000 All 80A
50.000
All 100A
70.000 All 160A
100.000 All 200A
3.000 All 10A
6.000
All 16A
9.000 All 20A
2.800
All 6A
4.200 All 10A
5.000
All 16A
10.000 All 25A
15.000 All 35A
2.800 All 6A
4.200
All 10A
5.000 All 16A
10.000 All 25A
15.000
All 35A
10.000
All 32A
15.000 All 50A
20.000 All 63A
30.000 All 100A
40.000 All 125A
50.000 All 160A
1.600 All 10A
2.500 All 16A
5.000 All 32A
10.000 All 63A
20.000
All 125A
NTN
NYN / MYN / HYN
typ. 90%
typ. 70-80%
HCK
HCH
MCP
HCP
typ. 86-93%
typ. 85%
typ. 90%
typ. 90%
typ 85%
typ 85%
NCA / MCA