Bipolar high voltage power supplies
Series HCB from ±1250 V to ±20000 V / 1,4 W to 200 W
Features:
Light-weight
In units with 6,5kV and higher
the HV-components are
moulded in (removable) sili-
con resin
Short-circuit and flash over
proof.
Unlimited operation with rated
current in a short-circuit con-
dition
Voltage regulation and current
limitation with automatic,
sharp transition, control
modes indicated by LEDs
Voltage adjustment with 10-
turn potentiometers with pre-
cision scale; the adjusting
knob can be locked
4½ digit DVM for voltage and
current (for table-top models)
Set point adjustment possible
with locked output, release of
output voltage by means of an
"ON" / "OFF" switch
4- quadrant operation possi-
ble also for active loads and
unlimited power sinking
Suitable for capacitive and
resistive loads
Function:
Bipolar HV power supplies
consist of 2 switch-mode con-
trolled HV sources which are
connected to the output. In
principle, the rectified line volt-
age in each source drives a
square wave generator of fixed
frequency, whose AC voltage is
transformed, rectified and fil-
tered, producing the positive or
negative output voltage. For
regulation, the square wave
voltage is pulse width modulat-
ed. The operation is contra-
moving, and the output can be
adjusted with continuous zero
crossing.
Design:
19" table-top case (19" rack
adaptors available)
Output:
Output isolation:
One output terminal each
leads the high voltage, the
"0V" terminal is connected
firmly to earth. If required, the
"0V" terminal can be made
floating against earth up to
±300V.
Output terminals:
All output terminals are locat-
ed at the rear plate of the
unit. High voltage connectors
with the appropriate dielectric
strength are delivered with
the power supply
Technical Data:
Mains connection:
Up to 700W nominal power:
230V ±10% 47Hz to 63Hz
For 1400W nominal power
and more:
400V±10% 47Hz to 63Hz,
three phase
Ambient temperature:
0°C to +40°C
The following data applies for
voltage regulation, and refers to
the rated value (unless other-
wise stated). (For explanations
please refer to Definitions and
Terms on page 54.)
Setting range:
from -100% to +100%
Setting resolution:
±1 x 10
-4
Residual ripple (0 - 10 MHz):
<3 x 10
-4
pp + 50mVpp,
typ. 2 x 10
-4
pp
Recovery time for voltage
control:
<1ms for load changes from
10% to 90% or from 90% to
10%
Setting time at nominal load:
<200ms
Deviation:
For ±10% mains voltage vari-
ation:
<± 2 x 10
-5
For no load / full load:
<2 x 10
-4
over 8 hours under constant
conditions:
<±2 x 10
-4
within the temperature range:
<±2 x 10
-4
/K
Possible Options:
Analog programming (see
page 44)
Analog programming, floating
(see page 44)
Computer interfaces - IEEE
488, RS 232, RS 422, Profi-
bus DP, USB, LAN (more on
request) (see page 46)
Lower ripple (see page 48)
Higher stability (see page 48)
Lower stored energy and
shorter recovery time (see
page 48)
More options and special solu-
tions on request. Some options
may involve changes to the
description of the unit - espe-
cially concerning the mechani-
cal design.
Design example
HCB 7 - 6500
± 6500V / ± 1mA