Linear regulated power supplies unipolar
Series NLN from 6,5 V to 500 V / 35 W to 1400 W
Features:
Voltage and current setting
with 10-turn potentiometers
with precision scale; the ad-
justing knob can be locked
Output voltage and output
current are fast programma-
ble
No output capacitor
All units are short circuit proof
and allow unlimited operation
with full current in short circuit
condition
Voltage and current regulation
with automatic and sharp
transition; control mode indi-
cated by LEDs
digit DVM for voltage and
current (for table-top models)
Sense terminals for the com-
pensation of voltage drop on
the load lines, for units up to
350V nominal voltage. The
rated voltage always refers to
the output terminals
Suitable also for inductive and
capacitive loads
Standard starting current
limitation from 700W nominal
power onwards
Function:
The mains voltage is trans-
formed to the appropriate level
and rectified. The rectified volt-
age charges a bank of capaci-
tors of the intermediate circuit
to a constant voltage, which it is
given via a set of power transis-
tors to the output. The series
transistor defines the final sta-
bility of the output voltage and
the regulation speed.
Optionally a set of power tran-
sistors parallel to the output can
act as a current sink to provide
active pull down ability. The de-
sign of linear regulated power
supplies is optimized for fast
programming speed.
Design:
For 35W nominal power -
½19" table-top case,
other models - 19" table-top
case (19" rack adaptors avail-
able)
Cooling: Convection or built-
in fan with air outlet on the
rear
Output:
Output isolation:
The output is floating. Operat-
ing voltage with respect to
earth: max. ±500V.
Each of the output terminals
may be connected to earth.
4mm safety connectors up to
20A on the rear panel. For
higher currents clamps in-
stalled on the rear.
Technical Data:
Mains connection:
Up to 1400W nominal power:
230V ±10% 47Hz to 63Hz
For 2800W and higher:
400V ±10% 47Hz to 63Hz,
three-phase
Ambient temperature:
0°C to +40°C
Power loss:
At nominal load approx. 25%,
during short circuit at nominal
current approx 125% of the
nominal power.
The following data applies for
voltage and current regulation,
and refers to the rated value
(unless otherwise stated):
(For explanations please refer
to Definitions and Terms from
page 54.)
Setting range:
from approx. 0,1% to 100%
Setting resolution:
±1 x 10
-4
Residual ripple (0 - 10MHz):
<5 x 10
-4
pp + 10mVpp
Recovery time:
<50µs for load changes from
10% to 100% or from 100% to
10%
Setting time at nominal load:
<1ms for full range
Deviation:
For ±10% mains voltage vari-
ation:
<± 2 x 10
-5
For no load / full load:
<2 x 10
-4
Over 8 hours under constant
conditions:
<±2 x 10
-4
Within the temperature range:
<±2 x 10
-4
/K
Possible Options:
Analog programming (The
positive output has to be
earthed; see also page 44)
Analog programming, floating
(see page 44)
DVM with higher resolution
Computer interfaces - IEEE
488, RS 232, RS 422, Profi-
bus DP, USB, LAN (more on
request) (see page 46)
Active pull-down control. Par-
allel to the output is a set of
power transistors operating as
a current sink. (see page 48)
Higher programming speed
More options and special solu-
tions on request. Some options
may involve changes to the
description of the unit - espe-
cially concerning the mechani-
cal design.
Design examples NLN 1400 - 20
20V / 60A