Power supplies for superconducting coils
Series NTS to 65 V / to 10000 A
Features:
High efficiency
Short circuit proof and with
unlimited operation at full
current in short-circuit condi-
tion
Sense terminals for the com-
pensation of the voltage drop
on the power lines. By pre-
setting the voltage, a linear
current ramp can be generat-
ed
Energizing and de-energizing
voltage can be preset with a
single potentiometer
Constant voltage operation for
linear up and down control
Linear de-energization, with
reverse voltage permitted up
to the nominal value of the
output voltage (2-quadrant
operation)
Interlock loop to monitor the
external load and internal loop
as a standard
Function:
Designed specifically for super-
conducting coil applications.
This power supply family is
series regulated, via a set of
parallel transistors, which are
driven from a pre-regulation
stage which utilises phase
controlled thyristors. In this
manner, the power lost across
the output transistors is kept to
minimum. Thus, the final con-
trol element always has a low
power dissipation in energizing
and static constant current
mode.
In de-energizing mode, the
transistor stage is working as a
current sink and the power is
dissipated by means of either
air or water cooling.
Cooling:
Up to approx. 1000A (or ap-
prox. 5kW de-energizing pow-
er), air cooling. For higher cur-
rents, or higher powers, water
cooling.
Design:
Up to 200A (or approx. 2.5
kW) in 19’’ table-top cases or
plug-in units.
Units with higher current or
power are supplied as 19"
cabinets on roller blades. The
side panels can be removed,
the rear door can be locked.
All cabinets have removable
crane-eyes.
Output:
Output isolation:
The output is floating. Operat-
ing voltage with respect to
earth: for air cooled units max.
±300V DC, for water cooled
units max. ±100V DC.
Output terminals:
Up to 100A, clamps on the
rear. For higher currents we
use copper bars.
Technical Data:
Mains connection:
Up to 1400W nominal power:
230V ±10% 47Hz to 53Hz
For 2800W and higher:
400V ±10% 47Hz to 53Hz,
two-phase
For 700W and higher:
400V ±10% 47Hz to 53Hz,
three-phase
Ambient temperature:
0°C to +40°C
All following data are guide
values and will be modified
according to the specification.
(For explanations please refer to
Definitions and Terms )
Setting range for current:
from approx. 0,1% to 100%
Setting range for voltage:
from -100% to +100%
Setting resolution:
±1 x 10
-4
to ±1 x 10-
6
Residual ripple (Voltage 0-
20MHz):
approx. 1 x 10
-3
pp
Residual ripple (Current 0-
20MHz):
±1 x 10
-4
pp to ±1 x 10
-6
pp
depending on inductivity of the
load
Run up time:
from 1sec. to 100 hours
Deviation:
For ±10% mains voltage vari-
ation:
<± 1 x 10
-5
For no load / full load:
<2 x 10
-4
Over 8 hours under constant
conditions:
<±1 x 10
-4
to ±1 x 10
-5
Within the temperature range:
<±1 x 10
-4
to ±5 x 10
-6
/K
Possible Options:
Analog programming (see
page 44)
Analog programming, floating
(see page 44)
DVM with higher resolution
Computer interfaces - IEEE
488, RS 232, RS 422, Profi-
bus DP, USB, LAN (more on
request) (see page 46)
Higher stability
Current control by electronic
ramp with digital control; rise
and fall times are adjustable
manually or via computer
interface
Current limit setting either
manually or via computer
interface. Resolution up to 1 x
10
-5
for external setting
High speed turn-off input with
adjustable threshold
Quench detector to monitor
the magnet
Fast de-energizing in the
event of quench or mains
failure: A DC circuit breaker or
a semiconductor switch dis-
connects the power supply
from the magnet. De-
energization takes place with
a power resistor, actuated at
quench, or via an external
circuit
Short circuit switch (Current
source 100mA for heating a
sector of the superconducting
circuit)
Water cooling
More options and special solu-
tions on request.
For this type of power supplies we don't indicate a range of standard types since it is
meaningful to adapt the power and equipment of the units for each single application.
NTS 250000M - 50
Front plate
Design examples