Technical data
27
©
FuG Elektronik GmbH, D-83135 Schechen, Am Eschengrund 11
http://www.fug-elektronik.de, E-Mail: info@fug-elektronik.de
V 0913
High voltage cassette power supplies EURO-size
Series HCE from 125 V to 35 kV / 7 W to 350 W
Features:
Compact size
Light-weight
For units from 6.5kV nominal
voltage on, all HV compo-
nents are moulded in (re-
movable) silicon
Short circuit and flashover
proof
Unlimited operation with rated
current in a short-circuit con-
dition
Unlimited operation with rated
power
Voltage or current regulation
with automatic transition.
Control mode indicated by
LEDs
Screwdriver adjustment of
voltage and current on the
front panel
Standard analog program-
ming plus HV ON/OFF input
and monitor outputs
Measuring terminals for volt-
age and current monitors on
the front panel
Suitable for use with capaci-
tive loads
Suitable for use with photo-
multipliers
Option:
Ten turn potentiometer for
voltage on the front panel.
Function:
In principle, the rectified line
voltage drives a square wave
generator of fixed frequency,
whose AC voltage is trans-
formed, rectified and filtered,
producing the output voltage.
For regulation, the square wave
voltage is pulse width modulat-
ed.
Design:
EURO-cassette design.
Width depending on type.
19" frames are available as
an option.
Output:
Output isolation:
The polarity is positive or
negative and has to be indi-
cated with the order. The
"0V" - terminal of the output is
connected to earth but may
be disconnected as needed.
When disconnected, the
"0V" (earthy) terminal may
float with respect to earth up
to ±125V.
Output terminals:
Outputs are located on the
rear of the units. For units up
to 650V nominal voltage, the
output is on 4mm safety con-
nectors.
From 1250V nominal voltage
on, HV-connectors are pro-
vided. The mating HV-
connectors are delivered with
the unit.
Technical Data:
Mains connection:
230V ±10% 47Hz to 63Hz
Ambient temperature:
0°C to +40°C
The following data applies for
voltage and current regulation,
and refers to the rated value
(unless otherwise stated):
(For explanations please refer to
Definitions and Terms on page
54.)
Setting range:
from approx. 0,1% to 100%
Setting resolution:
±1 x 10
-4
Residual ripple (0-10MHZ):
In CV mode:
<1 x 10
-4
pp + 50mVpp,
typ. 5 x 10
-5
pp
In CC mode:
<5 x 10
-4
pp + 50mVpp
Recovery time:
Voltage control:
<1ms for load changes from
10% to 100% or from 100% to
10%
Current control:
<10ms for load changes caus-
ing an output change of less
than 10% of the rated voltage
Setting time at nominal load:
<200ms for changes of the
output voltage from 10% to
90% or 90% to 10%
Discharge time constant
for output without load:
approx. 0,5sec. to 5sec.,
depending on type
Deviation:
For ±10% mains voltage vari-
ation:
<± 1 x 10
-5
For no load / full load:
<2 x 10
-4
Over 8 hours under constant
conditions:
<±1 x 10
-4
Within the temperature range:
<±1,5 x 10
-4
/K
Voltage and current adjustment
by screwdriver or via analog
programming.
HCE 7 - 12500
12,5kV / 0,5mA
positive
Design example HCE 35 - 35000
35kV / 1mA
negative
HCE 7 - 3500
3,5kV / 2mA
positive (2 units)
HCE 350 - 2000
2kV / 150mA
positive